7. INSTALLATION INSTRUCTIONS

7-1. Installation Site Selection

7-1-1. Indoor Unit
WARNING
AVOID:
direct sunlight.
nearby heat sources that may affect performance of
the unit.
areas where leakage of flammable gas may be
expected.
places where large amounts of oil mist exist.
DO:
select an appropriate position from which every corner
of the room can be uniformly cooled. (High on a wall
is best.)
select a location that will hold the weight of the unit.
select a location where tubing and drain hose have
the shortest run to the outside.
allow room for operation and maintenance as well as
unrestricted air flow around the unit. (Fig. 1)
install the unit within the maximum elevation
difference (H) above or below the outdoor unit and
within a total tubing length (L) from the outdoor unit as
detailed in Table 1 and Fig. 2.
Install the indoor unit more than 1 meter away from
any antenna or power lines or connecting wires used
for television, radio, telephone, security system, or
intercom. Electrical noise from any of these sources
may affect operation.
Table 1
Max. Allowable Tubing
Length at Shipment
Model
KRV94 / 124
* If total tubing length becomes 7.5 to 15 m, charge additional refrigerant (R410A) by 15 g/m.
No additional charge of compressor oil is necessary.
To prevent abnormal heat
generation and the possibility
of fire, do not place obstacles,
enclosures and grilles in front
of or surrounding the air
conditioner in a way that may
block air flow.
(m)
7.5
For stable operation of
the air conditioner, do not
install wall-mounted type
indoor units less than
1.5 m from floor level.
Limit of Tubing
Length (L)
(m)
15
22
15 cm min.
5 cm
min.
Front View
Fig. 1
Tubing length (L)
INDOOR
UNIT
Elevation
OUTDOOR
difference (H)
UNIT
Fig. 2
CAUTION
Fig. 3
Limit of Elevation
Difference (H)
(m)
10
5 cm
min.
Indoor unit
Wall
Minimum height
from floor level
1.5 m
Floor level
Required Amount of
Additional Refrigerant
(g/m)*
15