Recommended Wiring; Power Requirements; Table 1-2 Acuix Ip Recommended Wiring; Table 1-3 Wire Gauge Required For Maximum Distance To Dome - Honeywell Acuix IP Series Installation Manual

Rugged housing and dome
Table of Contents

Advertisement

ACUIX IP Rugged Housing and Dome

Recommended Wiring

Power Requirements

12
Type
Ethernet
Power
Alarm
The outdoor ACUIX requires a 24 VAC power supply @ 2.6 A, measured at the dome.
Refer to
Table 1-3
and
Table 1-4
one power source for one ACUIX and the required power supplies for CE compliance.
Table 1-3
Wire Gauge Required for Maximum Distance to Dome
AWG
24 VAC Camera plus Heater & Blower (2.6 A)
22
29 feet (8.8 meters)
20
45 feet (13.7 meters)
18
72 feet (21.9 meters)
16
115 feet (35.1 meters)
14
183 feet (55.8 meters)
12
291 feet (88.7 meters)
Table 1-4
Power Supplies
Model Number
Description
HPTV2404
4 Output, 24 VAC, 4A
HPTV2404CB
4 Output, 24 VAC, 4A, PTC
HPTV2404WP
4 Output, 24 VAC, 4A. NEMA4X Weatherproof enclosure
HPTV2404WP-2
4 Output, 24 VAC, 8A, NEMA4X Weatherproof enclosure
HPTV2401S
Single Output, 24 VAC, 8A, Indoor (includes power and video
surge suppression)
HPTV2401Z
Single Output, 24 VAC, 8A, Indoor (includes power, video, and
data surge suppression)
HPTV2401WPS
Single Output, 24 VAC, 8A, Weatherproof (includes power and
video surge suppression)
HPTV2401WPZ
Single Output, 24 VAC, 8A, Weatherproof (includes power, video,
and data surge suppression)
Table 1-2
ACUIX IP Recommended Wiring
Recommended Cable
CAT5 or above
18 AWG 2-Conductor, Vinyl
Jacket
20 gauge unshielded twisted
pair
to determine the wire sizes and maximum distances for
Maximum Distance
328 feet (100 meters)
See gauge chart for each
unit
10,000 feet (348 meters)

Advertisement

Table of Contents
loading

Table of Contents