Physical Data; Accessories; Accessory Description And Usage - Carrier SYNERGY 2000 38YDA Product Data

Two-speed electric heat pump
Table of Contents

Advertisement

Physical data

UNIT SIZE-SERIES
OPERATING WEIGHT (Lb)
REFRIGERANT
Cooling Control
Heating Piston
CHARGE (Lb)
COND FAN
Air Discharge
Air Qty (CFM) — High Speed
COND COIL
Face Area (Sq Ft)
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIG TUBES*
(In. OD)
Vapor
Liquid
* Tube sizes are for runs up to 100 ft. Maximum tube set length is 100 ft.
NOTE: See unit Installation Instructions for proper installation.

Accessories

ORDERING
NUMBER
KHASS0206MPK
KSASF0101AAA
KHATX1501HSO
P504-8163S (RCD)
THERMOSTAT AND SUBBASE
TSTATCCN2S01-A
TSTATCCP2S01-A
TSTATCCSEN01
Accessory description and usage (Listed alphabetically)
Filter Drier — Bi-flow
1.
A device for removing contaminants from refrigerant circulating in a heat pump system: 2-direction flow.
SUGGESTED USE: Split-system heat pumps.
2.
Snow Stand
Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base.
SUGGESTED USE: Heat pump installations in heavy snowfall areas.
Heat pump installations in snowdrift locations.
Heat pump installations in areas of prolonged subfreezing temperatures.
All commercial installations.
Support Feet
3.
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base;
minimizes corrosion.
SUGGESTED USE: Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
4.
Thermostatic Expansion Valve (TXV) — Bi-Flow
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RBP valves are available.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Required for use on all zoning applications.
036-30
316
57
15.6
Snow Stand
Support Feet (4)
Thermostatic Expansion Valve (Required)
Filter Drier — Bi-flow
Carrier Thermostat, Auto Changeover, Non-Programmable, ° F/ ° C, 2-stage heat/2-stage cool in AC mode,
3-stage heat/2 stage cool in HP mode
Carrier Thermostat, Auto Changeover, 7-Day Programmable, ° F/ ° C, 2-stage heat/2-stage cool in AC mode,
3-stage heat/ 2-stage cool in HP mode
Outdoor Sensor
048-30
316
22
TXV
70
14.6
Propeller Type, Direct Drive
Vertical
2650
Copper Tube, Aluminum Plate Fin
18.0
Sweat
7/8
3/8
7/8
3/8
DESCRIPTION
DESCRIPTION
060-30
318
70
14.4
3200
1-1/8
3