Download Print this page

Carrier Comfort 25HCR3C Product Data

13 series coastal heat pump with r-22 refrigerant 1-1/2 to 5 nominal tons (size 18 to 60)

Advertisement

Quick Links

25HCR3C
Comfortt 13 Series Coastal Heat Pump
with R---22 Refrigerant
1---1/2 to 5 Nominal Tons (Size 18 To 60)

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
EFFICIENCY
S
S
S
SOUND
S
S
COMFORT
S
RELIABILITY
S
S
S
S
S
S
S
S
DURABILITY
WeatherArmort protection package:
S
S
S
APPLICATIONS
S
S
WARRANTY
S
13 SEER/ 10.8 EER / 8.0 - - 8.5 HSPF (nominal)
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 71 dBA
Compressor sound blanket
System supports Thermidistatt or standard thermostat
controls
Armor Platet coil fin corrosion protection
Front- -seating service valves
Scroll compressor
Internal pressure relief valve
Internal thermal overload
High and Low pressure switch
Filter drier
Balanced refrigeration system for maximum reliability
Solid, durable sheet metal construction
Louvered coil guard
Baked- -on, complete coverage, powder paint
Long- -line - - up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 60 ft. (18.29 m) evaporator above
condenser (See Longline Guide for more information.)
Low ambient (down to - -20_F/- -28.9_C) with accessory
kit
10 year limited compressor warranty / 5 yr parts

Advertisement

loading

Summary of Contents for Carrier Comfort 25HCR3C

  • Page 1: Product Data

    25HCR3C Comfortt 13 Series Coastal Heat Pump with R---22 Refrigerant 1---1/2 to 5 Nominal Tons (Size 18 To 60) Product Data INDUSTRY LEADING FEATURES / BENEFITS EFFICIENCY 13 SEER/ 10.8 EER / 8.0 - - 8.5 HSPF (nominal) Microtube Technologyt refrigeration system...
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Product Major Cooling Minor Tier SEER Variations Open Open Voltage Series Family Series Capacity Series 0=Not 0=Not 25 = HP H = RES HP C=Comfort R = R---22 3=13 SEER C = Coastal 3=208/230 ---1 0, 1, 2... Defined Defined ISO 9001:2000...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE ---SERIES, VOLTAGE 18---30 24---30 30---30 36---30 42---30 48---30 60---30 Operating Weight lb (kg) (93.9) (92.5) (95.7) (114.3) (108.4) (142.4) (163.8) Shipping Weight lb (kg) (98.9) (107.1) (100.7) (130.2) (113.4) (157.9) (179.2) Compressor Type Scroll REFRIGERANT Freon (R--- 22) Control TXV (R--- 22 Hard Shutoff) 13.5...
  • Page 4 * Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non ---programmable air conditioner version and builder;s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
  • Page 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR LONG REQUIRED FOR SEA Accessory LOW---AMBIENT APPLICATIONS LINE APPLICATIONS* COAST APPLICATIONS (Below 55° F / 12.78° C) (Over 80 Ft. / 24.38 m) (Within 2 miles / 3.22 km) Ball Bearing Fan Motor Yes{ Compressor Start Assist Yes{...
  • Page 6 Heat pump installations in areas of prolonged 12. Outdoor Air Temperature Sensor subfreezing temperatures. Designed for use with Carrier Thermostats listed in this All commercial installations. publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special 17.
  • Page 7: Electrical Data

    ELECTRICAL DATA OPER VOLTS* COMPR WIRE WIRE LENGTH LENGTH FUSE** UNIT SIZE V/PH SIZE† SIZE† ft.(m)‡ ft.(m)‡ or BRK AMPS 60˚ C 75˚ C 60˚ C 75˚ C 12.7 (37.80) (35.97) 15.13 19.6 (23.16) (23.16) 72.5 13.50 18.6 (25.91) (24.69) 103| 208/230/1--- 60 18.68...
  • Page 9 MBTUH CAPACITY, HEATING INTEGRATED UNIT LOSS, HEAT BUILDING...
  • Page 10 COMBINATION RATINGS ARI Standard Ratings Unit Cooling Heating Cooling Size --- Indoor Model Capa- High Temp Low Temp Voltage, Furnace Model Factory Standard SEER city HSPF Series Enhance Rating Capacity Capacity *FA4CN(F,C)018 17,000 TDR&TXV 13.00 10.80 18,000 3.40 10,500 2.30 FA4CN(F,C)024 17,000 TDR&TXV...
  • Page 11 COMBINATION RATINGS (CONT.) ARI Standard Ratings Unit Cooling Cooling Heating Size --- Capa- Indoor Model High Temp Low Temp Voltage, Furnace Model Factory Standard SEER city HSPF Series Enhance Rating Capacity Capacity CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.52 58CV(A,X)135---22 CNRH*2417A**...
  • Page 12 COMBINATION RATINGS (CONT.) ARI Standard Ratings Unit Cooling Cooling Heating Size --- Capa- Indoor Model High Temp Low Temp Voltage, Furnace Model Factory Standard SEER city HSPF Series Enhance Rating Capacity Capacity CAR**3614A** 28,600 TDR&TXV 13.00 10.80 28,200 3.30 17,100 2.28 58CV(A,X)070---12 CAR**3617A**...
  • Page 13 COMBINATION RATINGS (CONT.) ARI Standard Ratings Unit Cooling Cooling Heating Size --- Capa- Indoor Model High Temp Low Temp Voltage, Furnace Model Factory Standard SEER city HSPF Series Enhance Rating Capacity Capacity *FC4DN(F,B)036 34,600 TDR&TXV 13.00 10.80 35,000 3.36 21,200 2.46 FC4DN(F,B)042 35,400...
  • Page 14 COMBINATION RATINGS (CONT.) ARI Standard Ratings Unit Cooling Cooling Heating Size --- Capa- Indoor Model High Temp Low Temp Voltage, Furnace Model Factory Standard SEER city HSPF Series Enhance Rating Capacity Capacity CSRH*3612A** 34,000 TDR&TXV 13.50 11.20 34,200 3.42 21,000 2.50 58CV(A,X)110---20 CSRH*3612A**...
  • Page 15 COMBINATION RATINGS (CONT.) ARI Standard Ratings Unit Cooling Cooling Heating Size --- Capa- Indoor Model High Temp Low Temp Voltage, Furnace Model Factory Standard SEER city HSPF Series Enhance Rating Capacity Capacity CNRH*4821A** 40,500 TDR&TXV 13.20 11.00 40,500 3.50 24,200 2.42 58MVB040---14 CNRH*4821A**...
  • Page 16 COMBINATION RATINGS (CONT.) ARI Standard Ratings Unit Cooling Cooling Heating Size --- Capa- Indoor Model High Temp Low Temp Voltage, Furnace Model Factory Standard SEER city HSPF Series Enhance Rating Capacity Capacity CAR**6024A** 46,500 TDR&TXV 13.50 11.20 46,000 3.38 29,600 2.58 58CV(A,X)135---22 CAR**6024A**...
  • Page 31 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM HEAT PUMP 25HCR3C GENERAL 1.5 TO 5 NOMINAL TONS System Description Compressor Outdoor- -mounted, air- -cooled, split- -system heat pump unit — Compressor will be hermetically sealed. suitable for ground or rooftop installation. Unit consists of a —...
  • Page 32 Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. edition date: 07/07 Catalog No: 25HCR3C ---2PD Replaces: 25HCR3C--- 1PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.