Heat pump heating performance continued
INDOOR
AIR
EDB
CFM
38YDA060-30 Outdoor Section in Low-Speed With FK4CNB006 Indoor Section
1115
1240
1365
65
1500
1625
1750
1115
1240
1365
70
1500
1625
1750
1115
1240
1365
75
1500
1625
1750
Indoor
Section
Size
F(A,B)4AN(F,B)
060
FB4ANB
070
FC4BN(F,B)
060
FC4BNB
070
FK4CNB
006
CC5A/CD5A/CD5BW
060
CD5A/CD5A/CD5BA
060
CD3(A,B)A
060
CE3AA
060
CJ5A/CK5A/CK5BA
060
CJ5A/CK5A/CK5BN
060
CJ5A/CK5A/CK5BX
060
CK3BA
060
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
060
CC5A/CD5A/CD5BW
060
CD3(A,B)A
060
CE3AA
060
CJ5A/CK5A/CK5BA
060
CJ5A/CK5A/CK5BN
060
* The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these
values to obtain total system kilowatts.
† The Btuh heating capacity values shown are net ''integrated'' values from which the defrost effect has been subtracted. The Btuh heating from sup-
plement heaters should be added to those values to obtain total system capacity.
EDB — Entering Dry Bulb
30
40
Capacity
Total
MBtuh
Power
Total
Integ†
Kw*
28.9
28.9
2.08
29.1
29.1
2.06
29.4
29.4
2.05
29.6
29.6
2.04
29.8
29.8
2.04
29.9
29.9
2.04
28.3
28.3
2.18
28.6
28.6
2.16
28.8
28.8
2.15
29.0
29.0
2.14
29.2
29.2
2.14
29.4
29.4
2.14
27.7
27.7
2.27
28.0
28.0
2.25
28.2
28.2
2.24
28.5
28.5
2.24
28.6
28.6
2.24
28.8
28.8
2.24
Multipliers for Determining the Performance With Other Indoor Sections
Heating
Capacity
Power
1.07
1.28
1.07
1.20
1.07
1.28
1.07
1.20
1.00
1.00
0.97
1.14
0.97
1.17
0.97
1.17
0.97
1.14
1.00
1.15
1.01
1.14
1.01
1.14
1.00
1.15
0.93
1.08
0.94
1.04
0.93
1.08
0.94
1.05
0.97
1.06
0.97
1.05
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
47
Capacity
MBtuh
Total
Integ†
32.1
32.1
32.4
32.4
32.6
32.6
32.8
32.8
33.0
33.0
33.2
33.2
31.5
31.5
31.8
31.8
32.1
32.1
32.3
32.3
32.5
32.5
32.7
32.7
30.9
30.9
31.2
31.2
31.5
31.5
31.7
31.7
31.9
31.9
32.1
32.1
Indoor
Section
CJ5A/CK5A/CK5BX
CK3BA
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CD3CA
CE3AA
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BX
CK3BA
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CD3CA
CE3AA
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BX
CK3BA
57
Capacity
Total
MBtuh
Power
Kw*
Total
Integ†
2.10
37.0
37.0
2.07
37.4
37.4
2.05
37.7
37.7
2.03
38.0
38.0
2.02
38.2
38.2
2.02
38.4
38.4
2.21
36.4
36.4
2.19
36.8
36.8
2.17
37.1
37.1
2.15
37.4
37.4
2.14
37.6
37.6
2.14
37.8
37.8
2.32
35.7
35.7
2.29
36.1
36.1
2.28
36.5
36.5
2.26
36.8
36.8
2.26
37.0
37.0
2.26
37.2
37.2
Heating
Size
Capacity
060
0.97
060
0.97
060
0.94
060
0.95
060
0.94
060
0.95
060
0.95
060
0.98
060
0.99
060
0.98
060
0.94
060
0.95
060
0.94
060
0.95
060
0.95
060
0.98
060
0.98
060
0.98
Total
Power
Kw*
2.12
2.07
2.03
2.00
1.98
1.97
2.25
2.21
2.17
2.15
2.13
2.11
2.37
2.33
2.30
2.28
2.26
2.25
Power
1.04
1.06
1.05
1.02
1.05
1.02
1.02
1.04
1.02
1.04
1.05
1.03
1.05
1.02
1.02
1.05
1.03
1.05