Carrier SYNERGY 2000 38YDA Product Data page 27

Two-speed electric heat pump
Table of Contents

Advertisement

Heat pump heating performance continued
INDOOR
AIR
Capacity
MBtuh
EDB
CFM
Total
38YDA048-30 Outdoor Section in Low-Speed With FK4CNB006 Indoor Section
895
21.4
995
21.7
1095
21.9
65
1200
22.1
1325
22.3
1450
22.5
895
20.7
995
21.0
1095
21.3
70
1200
21.5
1325
21.7
1450
21.9
895
20.0
995
20.3
1095
20.5
75
1200
20.8
1325
21.0
1450
21.2
Indoor
Section
Size
F(A,B)4AN(F,B)
048
060
FB4ANB
070
FC4BN(F,B)
048
060
FC4BNB
070
FK4CNB
006
FK4CNF
005
CC5A/CD5A/CD5BA
060
CC5A/CD5A/CD5BW
048
060
CD5A/CD5BA
048
CD3(A,B)A
048
060
CE3AA
048
060
CF5AA
048
CJ5A/CK5A/CK5BA
048
060
CJ5A/CK5A/CK5BN
060
CJ5A/CK5A/CK5BW
048
CJ5A/CK5A/CK5BX
060
CK3BA
048
060
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
060
CC5A/CD5A/CD5BW
048
060
CD5A/CD5BA
048
CD3(A,B)A
048
060
CE3AA
048
060
CJ5A/CK5A/CK5BA
048
060
CJ5A/CK5A/CK5BN
060
See notes on pg. 30.
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
33
Capacity
Total
MBtuh
Power
Integ†
Kw*
Total
18.4
1.81
23.0
18.7
1.80
23.3
18.9
1.80
23.5
19.0
1.80
23.7
19.2
1.79
23.9
19.4
1.80
24.1
17.8
1.87
22.4
18.1
1.86
22.7
18.3
1.86
22.9
18.5
1.85
23.1
18.7
1.85
23.4
18.9
1.86
23.5
17.2
1.92
21.7
17.5
1.92
22.0
17.7
1.91
22.3
17.9
1.91
22.5
18.1
1.91
22.7
18.3
1.92
23.0
Multipliers for Determining the Performance With Other Indoor Sections
Heating
Capacity
Power
1.00
1.26
1.00
1.30
1.07
1.24
1.00
1.26
1.00
1.30
1.07
1.24
1.00
1.00
0.97
1.02
1.00
1.16
1.00
1.16
1.00
1.14
1.00
1.16
1.00
1.16
1.00
1.16
1.00
1.16
1.00
1.14
1.00
1.17
1.01
1.15
1.01
1.15
1.02
1.14
1.01
1.15
1.02
1.14
1.01
1.15
1.01
1.15
0.97
1.04
0.96
1.04
0.97
1.02
0.96
1.04
0.96
1.04
0.96
1.04
0.96
1.06
0.96
1.04
0.97
1.05
0.97
1.04
0.98
1.03
37
Capacity
Total
MBtuh
Power
Integ†
Kw*
Total
20.9
1.85
27.1
21.2
1.84
27.4
21.4
1.83
27.7
21.6
1.82
27.9
21.8
1.82
28.2
21.9
1.81
28.4
20.4
1.91
26.5
20.6
1.90
26.8
20.9
1.89
27.1
21.1
1.88
27.3
21.2
1.88
27.6
21.4
1.88
27.8
19.7
1.97
25.9
20.0
1.96
26.2
20.2
1.95
26.5
20.5
1.95
26.7
20.7
1.95
27.0
20.9
1.95
27.2
Indoor
Section
CJ5A/CK5A/CK5BX
CK3BA
COILS + 58U(H,X)V080-16 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BC
CC5A/CD5A/CD5BW
CD5A/CD5BA
CD3(A,B)A
CD3CA
CE3AA
CJ5A/CK5A/CK5BA
CK3A
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BC
CC5A/CD5A/CD5BW
CD5A/CD5BA
CD3(A,B)A
CD3CA
CE3AA
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CJ5A/CK5A/CK5BX
CK3BA
47
Capacity
Total
MBtuh
Power
Integ†
Kw*
Total
27.1
1.93
31.7
27.4
1.91
32.1
27.7
1.89
32.5
27.9
1.87
32.8
28.2
1.86
33.2
28.4
1.85
33.4
26.5
2.0
31.0
26.8
1.98
31.4
27.1
1.96
31.8
27.3
1.95
32.1
27.6
1.94
32.4
27.8
1.93
32.7
25.9
2.07
30.3
26.2
2.05
30.8
26.5
2.04
31.1
26.7
2.03
31.4
27.0
2.02
31.7
27.2
2.01
32.0
Heating
Size
Capacity
060
0.98
048
0.97
060
0.97
060
0.96
048
0.96
048
0.96
060
0.96
048
0.96
048
0.96
060
0.96
048
0.96
060
0.96
048
0.96
060
0.96
048
0.96
048
0.96
060
0.96
060
0.95
048
0.95
048
0.95
060
0.96
048
0.95
048
0.95
060
0.95
048
0.95
060
0.96
048
0.95
060
0.96
060
0.97
048
0.97
060
0.98
048
0.97
060
0.97
57
Total
Power
Integ†
Kw*
31.7
2.01
32.1
1.97
32.5
1.95
32.8
1.92
33.2
1.90
33.4
1.89
31.0
2.10
31.4
2.06
31.8
2.03
32.1
2.01
32.4
1.99
32.7
1.98
30.3
2.18
30.8
2.14
31.1
2.12
31.4
2.10
31.7
2.08
32.0
2.06
Power
1.02
1.04
1.04
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.95
0.96
1.04
1.04
1.04
1.04
1.05
1.03
1.02
1.03
1.03
1.04
1.03
1.02
1.03
1.01
1.02
1.03
1.01
1.03
1.02
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents