Detailed cooling capacities* continued
EVAPORATOR
AIR
Capacity
MBtuh†
Total
CFM
EWB
38YDA048-30 Outdoor Section in High-Speed With FK4CNB006 Indoor Section continued
72
55.5
67
50.5
1070
63‡‡
46.9
62
45.9
57
42.6
72
56.8
67
51.7
1200
63‡‡
48.1
62
47.1
57
44.5
72
57.8
67
52.7
1325
63‡‡
49.0
62
48.0
57
46.1
72
58.8
67
53.6
1470
63‡‡
49.9
62
49.0
57
47.7
72
59.7
67
54.5
1625
63‡‡
50.6
62
49.9
57
49.2
Indoor
Section
Size
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
060
CC5A/CD5A/CD5BC
048
CC5A/CD5A/CD5BW
048
060
CD5A/CD5BA
048
CD3(A,B)A
048
060
CD3CA
048
060
CE3AA
048
060
CJ5A/CK5A/CK5BA
060
CJ5A/CK5A/CK5BW
048
CJ5A/CK5A/CK5BX
060
CK3BA
048
060
See notes on pg. 20.
16
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Total
MBtuh†
System
Sens‡
Total
Kw**
26.6
4.69
53.0
32.4
4.54
48.2
31.6
4.42
44.7
38.1
4.39
43.8
42.6
4.28
40.9
27.7
4.76
54.1
34.2
4.61
49.3
33.3
4.49
45.8
40.6
4.46
44.8
44.5
4.38
42.8
28.7
4.83
55.0
35.8
4.67
50.2
34.9
4.55
46.6
42.8
4.52
45.7
46.1
4.46
44.3
29.8
4.89
55.9
37.7
4.74
51.0
36.6
4.62
47.4
45.4
4.59
46.7
47.7
4.55
45.8
31.0
4.95
56.6
39.6
4.80
51.8
38.4
4.68
48.1
47.9
4.66
47.6
49.2
4.64
47.2
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Sensible††
0.92
0.87
0.92
0.89
0.92
0.87
0.94
0.91
0.92
0.87
0.92
0.87
0.92
0.87
0.91
0.86
0.92
0.89
0.92
0.90
0.94
0.93
0.92
0.92
0.92
0.92
0.94
0.94
0.92
0.92
0.94
0.94
95
Capacity
Total
MBtuh†
System
Sens‡
Total
Kw**
25.6
5.04
50.5
31.4
4.86
45.9
30.6
4.73
42.4
37.1
4.69
41.6
40.9
4.57
39.2
26.7
5.11
51.5
33.2
4.94
46.8
32.3
4.80
43.5
39.5
4.77
42.6
42.8
4.68
40.9
27.7
5.18
52.3
34.8
5.00
47.7
33.8
4.87
44.2
41.7
4.83
43.4
44.3
4.78
42.4
28.7
5.25
53.1
36.6
5.07
48.4
35.5
4.94
44.9
44.2
4.91
44.3
45.8
4.87
43.9
29.9
5.31
53.7
38.5
5.13
49.1
37.3
5.00
45.6
46.7
4.98
45.2
47.2
4.97
45.2
Indoor
Power
Section
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
0.96
CC5A/CD5A/CD5BA
0.88
CC5A/CD5A/CD5BC
0.96
CC5A/CD5A/CD5BW
0.97
0.96
CD5A/CD5B
0.96
CD3(A,B)A
0.96
0.94
CD3CA
0.95
0.97
CE3AA
0.97
0.99
CJ5A/CK5A/CK5BA
0.98
CJ5A/CK5A/CK5BW
0.99
CJ5A/CK5A/CK5BX
0.98
CK3BA
0.99
105
Capacity
Total
MBtuh†
System
Sens‡
Total
Kw**
24.6
5.39
47.9
30.4
5.18
43.3
29.6
5.02
40.0
36.0
4.97
39.1
39.2
4.86
37.4
25.7
5.47
48.8
32.1
5.27
44.3
31.2
5.10
40.9
38.4
5.06
40.1
40.9
4.98
39.0
26.7
5.54
49.5
33.8
5.33
45.0
32.7
5.17
41.6
40.7
5.14
40.9
42.4
5.09
40.4
27.8
5.61
50.2
35.6
5.41
45.7
34.5
5.24
42.3
43.1
5.21
41.9
43.9
5.20
41.8
28.9
5.68
50.8
37.5
5.47
46.3
36.2
5.32
42.9
45.2
5.30
43.1
45.2
5.30
43.0
Cooling
Size
Capacity
Sensible††
060
0.92
0.87
048
0.92
0.86
048
0.92
0.87
060
0.94
0.90
048
0.92
0.87
048
0.92
0.87
060
0.92
0.87
048
0.91
0.85
060
0.92
0.89
048
0.92
0.90
060
0.94
0.93
060
0.92
0.92
048
0.92
0.92
060
0.94
0.94
048
0.92
0.92
060
0.92
0.92
115
Total
System
Sens‡
Kw**
23.7
5.73
29.4
5.48
28.5
5.28
34.9
5.23
37.4
5.12
24.7
5.82
31.1
5.57
30.1
5.38
37.3
5.33
39.0
5.26
25.7
5.89
32.7
5.65
31.6
5.45
39.5
5.41
40.4
5.38
26.7
5.97
34.5
5.72
33.3
5.53
41.7
5.50
41.8
5.50
27.9
6.04
36.4
5.80
35.1
5.61
43.1
5.62
43.0
5.62
Power
0.97
0.97
0.97
0.98
0.96
0.97
0.97
0.95
0.96
0.98
0.98
0.99
0.99
1.00
0.99
0.99

Hide quick links: