Assembly; Installation; Installation, Hydraulic - ProMinent Makro TZ Operating Instructions Manual

Metering pumps
Table of Contents

Advertisement

Ambient temperature -10 C to 40 C
Humidity Max. 95 % rel. humidity, non-condensing
Priming pressure: Maximum permissible priming pressure (suction side): 1 bar
Viscosity The liquid ends are designed for a maximum viscosity of:
ProMinent
®
6

Assembly

The pump must be bolted to an even, stable base. The base must be capable of permanently
bearing the weight of the pump. Bolt the pump with the four bolts (M8) through the four bore
holes in the frame into the pump feet or base if applicable.
When fixed, the pump must not vibrate.
NOTICE
®
Contact ProMinent
if retrofitting an add-on pump.
7

Installation

WARNING
EX pump only: Always observe the "Important supplements for dosing pumps in EX areas"
section of the "General Operating Instruction for ProMinent
and Hydraulic Accessories"!
NOTICE
Also note "General Operating Instruction Manual for ProMinent
pumps and Hydraulic Accessories"!
7.1

Installation, hydraulic

Liquid end
WARNING
• The liquid ends may still contain traces of water from the factory tests! If using with
media which must not come into contact with water, ensure that the liquid ends are
dried before installation. Dry with compressed air. Then rinse out by inserting a suitable
rinse aid through the suction connection.
• The discharge line should be arranged to ensure that the maximum admissible pump
and system operating pressures are not exceeded during the discharge stroke.
NOTICE
• It is necessary to install a filter in the suction line for the piston liquid end if using with
media with particle sizes greater than 0.3 mm.
• Accurate metering is possible only at a constant back pressure above 1 bar.
If metering at atmospheric pressure, use a back pressure valve to generate a back
pressure of approx. 1.5 bar.
200 mPa s
valves without valve springs
500 mPa s
valves with valve springs
1000 mPa s
correspondingly designed installation
> 1000 mPa s
correspondingly designed installation and after consultation with ProMinent
Leakage discharge (TZMb, TZMa and TZKa only)
Leakage fluid is drained off via the flushing collar and a hose nozzle. No other liquid end parts
come into contact with the fluid.
Connect a hose to the lower hose nozzle
Feed the hose into a leakage fluid bund.
Assembly / Installation
®
Motor-Driven Metering Pumps
®
Motor-Driven Metering
Page 21