with 1500 rpm motor at 50 Hz
Capacity
at max.
back pressure
Pump type
bar
l/h
TZMbH
120260
12
120340
12
120430
12
120510
12
120650
12
070430
7
070570
7
070720
7
070860
7
071070
7
1070
040840
4
041100
4
1100
041400
4
1400
041670
4
1670
042100
4
2100
Material version PPT/PCT/TTT 10 bar max.
The permissible priming pressure on the suction side is approx. 50 % of the max. permissible back pressure.
With dual head pumps, the maximum permissible back pressure is reduced from 7 to 5.5 bar and from 4 to 3 bar
respectively (from 101.5 psi to 80 psi and from 58 psi to 43.5 psi respectively).
All figures apply for water at 20 C.
The suction lift applies for filled suction line and liquid end - with correct installation.
The priming lift of 2 m applies for clean and wetted valves and free discharge
(the values reduce with valve springs!).
Identity Code
special feature
S
3 ph, IP 55
L1
3 ph, II2GEEXeIIT3
L2
3 ph, II2GEEXdIICT4
P1 3 ph, II2GEEXeIIT3
P2 3 ph, II2GEEXdIICT4
R
3 ph, IP 55
V0 3 ph, IP 55
V2 3 ph, II2GEExdIICT4
Please request motor data sheets for more information.
Special motors and motor flanges are possible on request.
ProMinent
®
14

Technical data

WARNING
Only for modified version: Please observe the "Supplement for modified version" at the end
of the section!
It replaces and supplements the technical data!
Table of main pumps diaphragm liquid ends (TZMb)
Max.
stroke
frequency
ml/
strokes/
stroke
min
260
60
72
340
60
96
430
60
120
510
60
144
640
60
180
430
99
72
570
99
96
720
99
120
860
99
144
99
180
840
194
72
194
96
194
120
194
144
194
180
Makro TZ (TZMb) motor data table
Supply
220-240 V/380-420 V
250-280 V/440-480 V
220-240 V/380-420 V
220-240 V/380-420 V
250-280 V/440-480 V
250-280 V/440-480 V
230 V/400 V
400 V 10 %
400 V 10 %
with 1800 rpm motor at 60 Hz
Capacity
at max.
back pressure
psi
l/h
gph
174
309
81.8
174
414
109.5
174
518
137
174
622
164.5
174
100
511
135
100
683
180
100
855
226
100
1028
272
100
58
1001
264
58
1339
354
58
1676
443
58
2014
532
58
Remarks
50 Hz
0.75 kW
60 Hz
0.75 kW
50 Hz
0.75 kW
50 Hz
0.75 kW
with PTC thermistor, speed control range 1:5
60 Hz
0.75 kW
60 Hz
0.75 kW
with PTC thermistor, speed control range 1:5
50/60 Hz 1.5 kW
with PTC thermistor, speed control range 1:20
with external fan 1ph 230 V; 50/60 Hz
50/60 Hz 1.5 kW
variable-speed motor with integrated
frequency converter
50/60 Hz 1.5 kW
Ex-variable-speed motor with integrated
frequency converter
Stroke
Suction Connection
count at
lift
suction/
max. back
discharge
pressure
side
strokes/
m WG
G-DN
min.
86
5
1 1/2 - 25
115
5
1 1/2 - 25
144
5
1 1/2 - 25
173
5
1 1/2 - 25
5
1 1/2 - 25
86
4
2 - 32
115
4
2 - 32
144
4
2 - 32
173
4
2 - 32
4
2 - 32
86
3
2 1/4 - 40
115
3
2 1/4 - 40
144
3
2 1/4 - 40
173
3
2 1/4 - 40
3
2 1/4 - 40
Technical data
Shipping
weight
PP, PC,
TT/SS
kg
46/54
46/54
46/54
46/54
46/54
50/64
50/64
50/64
50/64
50/64
56/80
56/80
56/80
56/80
56/80