Diaphragm rupture sensor Standard: 30 V DC/ 1A, volt-free contact (closed in normal condition).
(for TZMb) For safety reasons, the application of a separated extra-low voltage is required
Diaphragm rupture sensor
(for TZHa) Contact rating:
Overpressure sensor Contact rating:
(TZHa only) Switching current: 0.5 A
ProMinent
®
Cable assignment:
blue
-
brown
+
(SELV in accordance with EN 60335-1).
Cable assignment: any
Intrinsically safe option: observe the enclosed operating instructions of the sensor
(EX pump only)!
5 – 25 V DC, in accordance with Namur and DIN 19234, volt-free arrangement.
Nominal voltage: 8 V DC (R
Current consumption:
active surface clear
active surface covered < 1 mA
Nominal contact spacing: 1,5 mm
The evaluation / supply device must be able to evaluate the changes in current in order to
indicate a diaphragm rupture.
Cable assignment:
Option
blue
-
brown
+
IMPORTANT
• The diaphragm rupture sensor must be connected electrically!
The customer must install suitable evaluation electronics for the diaphragm rupture
signal and it must be ensured that the dosing pump is switched off after a diaphragm
rupture signal!
0.1 A, 250 V AC/DC
Contact type:
normally closed (microswitch)
Protection class: IP67
Cable assignment:
blue
-
brown
+
10 W / 12 VA
Switching voltage: 48 V
Contact type:
normally closed (reed contact)
Protection class: IP67
Cable assignment:
white
-
brown
+
~ 1 k)
i
> 3 mA
Installation