Sound intensity level The sound intensity level is < 70 dB (A)
ProMinent
®
Safety / Storage, transport, unpacking / Device overview, controls
at max. strokes, max stroke rate, max back pressure (water) in accordance with:
DIN EN 12639 (Noise measurement, fluid pumps)
3
Storage, transport, unpacking
The pump is delivered on a pallet.
NOTICE
• The pump is filled with oil on delivery.
• Never lift the pump by the turret or the liquid end.
• The pump must be placed on a level, stable base.
Ambient conditions for storage and transport
Temperature
Humidity:
Shipping weight: see "Technical data" table
4
Device overview, controls
1
C
Fig. 3
Makro TZMa
-10 C to 50 C
max. 95 % relative humidity, non-condensing
2
3
A
A Power end
C Liquid end
4
1 Vent screw
2 Stroke adjustment wheel
5
3 Oil inspection window
4 Motor
5 Oil drain plug
Page 11