Accessory Usage Guideline - Carrier 38CKS Product Data

(60 hz) 10 seer air conditioner export models sizes 018 thru 060
Table of Contents

Advertisement

THERMOSTAT PKG.
TSTATCCPRH01-B
TSTATCCPAC01-B
TSTATCCNAC01-C
TSTATCCBAC01-B
TSTATXXSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXBBP01
TSTATXXCNV10

Accessory usage guideline

ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay
MotorMaster®—Low-Ambient
Controller
or Low-Ambient Pressure Switch
Wind Baffle
Coastal Filter
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
Ball Bearing Fan Motor
* For tubing line sets between 50 (15.24m) and 175 ft (53.34m) and/or 20 ft (6.1m) vertical differential, refer to Residential Split Systems Long-Line
Application Guideline.
† Only when low-pressure switch is used.
‡ Required for Low-Ambient Controller MotorMaster® Control only.
Accessory description and usage (Listed alphabetically)
1. Ball-Bearing Fan Motor
A fan motor with ball bearings, which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMaster®—Low-Ambient Controller is installed.
2. Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
3. Compressor Start Assist – Capacitor and Relay
Start capacitor and relay gives a "hard" boost to compressor motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the following applications:
Long line
Low ambient
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for scroll compressors in the following applications:
Long line
Low ambient
Suggested for all compressors in areas with a history of low voltage problems.
4. Compressor Start Assist – PTC Type
Solid-state electrical device which gives a "soft" boost to the compressor motor at each start up.
Usage Guideline:
Suggested when compressor power supply is marginal
Suggested in reciprocating compressor applications with rapid pressure balance (RPB) expansion valve on indoor coil.
Thermidistat Control, Programmable/Non-Programmable Thermostat with Humidity Control
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
Builder's Thermostat, Manual Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat
Backplate for Builder's Thermostat
Thermostat Conversion Kit (4 to 5 wire) — 10 Pack
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
Yes
Yes
Yes†
No
Yes
Yes
See Low-Ambient
Instructions
No
No
Yes‡
DESCRIPTION
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
Yes
No
No
No
Yes
No
No
No
See
Long-Line
Application Guideline
No
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
No
No
No
No
No
No
No
No
No
No
5