Accessories Description And Usage; Accessory Usage Guideline - Carrier 24APA7 Performance Product Data

Performance 17 2-stage air conditioner with puron refrigerant 2 to 5 tons
Hide thumbs Also See for 24APA7 Performance:
Table of Contents

Advertisement

ACCESSORIES
ORDER NUMBER
KSAHS2301AAA
KSAHS2401AAA
KSAHS2501AAA
KSAHS2601AAA
KSASF0101AAA
KSATX0201PUR
KSATX0301PUR
KSATX0401PUR
KSATX0501PUR
x = Accessory

ACCESSORY USAGE GUIDELINE

ACCESSORY
Crankcase Heater
Evaporator Freeze Protection
Liquid --- Line Solenoid Valve
Low--- Ambient Control
Puron Refrigerant Balance Port Hard ---
ShutOff TXV
Support Feet
Winter Start Control
* For tubing set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 35 ft. (10.7 m) vertical differential (total equivalent length), refer to the Long
Line Guideline—Air Conditioners and Heat Pumps using Puron® Refrigerant.
{ Required on all indoor units. Standard on all new Puron refrigerant fan coils and furnace coils.
Accessory Description and Usage (Listed Alphabetically)
1. Compressor Start Assist - - Capacitor and Relay
Start capacitor and relay gives a "hard" boost to compressor
motor at each start up.
Usage Guideline:
Not required on this unit since compressor always starts
unloaded.
Available if required by local codes.
2. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles.
Improves compressor lubrication on restart and minimizes the
chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
DESCRIPTION
HARD START KIT
HARD START KIT
HARD START KIT
HARD START KIT
SUPPORT FEET
TXV PURON HSO
TXV PURON HSO
TXV PURON HSO
TXV PURON HSO
REQUIRED FOR
LOW --- AMBIENT COOLING
APPLICATIONS
(Below 55°F/12.8_C)
Standard
Standard with Infinityt Control
(Low Ambient not allowed with
non ---communicating thermostat)
No
Standard with Infinity Control
(Low ambient not allowed with
non ---communicating thermostat)
Yes
{
Recommended
Standard with Infinity Control
(Low Ambient not allowed with
non ---communicating thermostat)
24--- 30
36--- 30
X
X
X
X
X
X
REQUIRED FOR LONG LINE AP-
PLICATIONS*
(Over 80 ft/24.38 m)
Standard
No
No
No
Yes{
No
No
3. Support Feet
Four stick- -on plastic feet that raise the unit 4 in. (101.6 mm)
above the mounting pad. This allows sand, dirt, and other debris
to be flushed from the unit base, minimizing corrosion.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
4. Thermostatic Expansion Valve (TXV)
A modulating flow- -control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube.
Hard shut off types are available.
NOTE: When using a hard shut off TXV with single phase
reciprocating compressors, a Compressor Start Assist Capacitor
and Relay is required.
Usage Guideline:
Required to achieve AHRI ratings in certain equipment
combinations. Refer to combination ratings.
Hard shut off TXV or LLS required in air conditioner
long line applications.
6
48--- 31
60--- 31
X
X
X
X
X
X
REQUIRED FOR SEA COAST
APPLICATIONS (Within 2
miles/3.22 km)
Standard
No
No
No
Yes
{
Recommended
No