Accessory Usage Guideline; Accessory Description And Usage (Listed Alphabetically); Ball Bearing Fan Motor; Compressor Start Assist — Ptc - Carrier 38CKS Product Data

60 hz air conditioner sizes 018 thru 060
Table of Contents

Advertisement

THERMOSTAT PKG.
TSTATCCPRH01-B
TSTATCCNAC01-B
TSTATCCPAC01-B
TSTATCCBAC01
TSTATXXSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXBBP01
TSTATXXCNV10

Accessory usage guideline

ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay
Low Ambient Controller,
MotorMaster® Control,
or Low-Ambient Pressure Switch
Wind Baffle
Coastal Filter
Unit Risers
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV

Ball Bearing Fan Motor

* For tubing line sets between 50 and 175 ft, refer to Residential Split Systems Long-Line Application Guideline.
† Only when low-pressure switch is used.
‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.

Accessory description and usage (Listed alphabetically)

Ball Bearing Fan Motor
1.
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.
2.
Compressor Start Assist — Capacitor and Relay
Start capacitor and start relay gives "hard" boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
Installations where outdoor design temperature exceeds 105°F (40.6°C).
Replacement installations with hard shutoff expansion valve on indoor coil.
Installations where Liquid-Line Solenoid Valve has been added.
3.
Compressor Start Assist — PTC
Solid-state electrical device which gives a "soft" boost to the compressor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.
4.
Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on
restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with low-ambient controller.)
All commercial installations.
Cycle Protector
5.
Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been
interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
Where user is likely to "play" with the room thermostat.
All commercial installations.
Installations where interconnecting tube length exceeds 50 ft.
High-rise applications.
Thermidistat Control, Programmable/Non-Programmable Thermostat with Humidity Control
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
Builder's Thermostat, Manual Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat
Backplate for Builder's Thermostat
Thermostat Conversion Kit (4 to 5 wire) — 10 Pack
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
Yes
Yes
Yes†
No
Yes
Yes
See Low-Ambient
Instructions
No
Recommended
No
Yes‡
DESCRIPTION
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
Yes
No
No
No
Yes
No
No
No
No
See
Long-Line
Application Guideline
No
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
No
No
No
No
No
No
No
No
Recommended
No
No
5