Master And Slave Operators With Timer - Elite Robo Slide Instruction Manual

Residential gate operator
Table of Contents

Advertisement

M A S T E R
To use the master/slave option with Robo Slide, you must purchase the Optional Input
Board (Elite Part # Q203) and connect it to the J2 slot.
Caution:
18 VAC plug-in transformer, per gate operator required
Master
Master J2 Plug
1. Make master/slave J2 plug connections as shown above
2. Turn timers on BOTH control boards to the "ON" position
3. Use MASTER timer ONLY for the auto close time adjustment (0 to 60 sec)
4. Turn the SLAVE timer adjustment all the way Counterclockwise
Master Timer "ON"
Set Timer
0 to 60 seconds
A N D
S L A V E
4 Low Voltage Wires Connect Gate Operators Together
Master Pin 5 to Slave Pin 7
Master Pin 1 to Slave Pin 1
Master Pin 6 to Slave Pin 8
Master Pin 2 to Slave Pin 2
W I T H
T I M E R
Refer to Optional Input Board
Slave Timer "ON"
Maximum
Counterclockwise
Setting
Slave
Slave J2 Plug