STEP 10: Two-Way Adjustable Reversing Sensor
There is a blue pot with a white screw adjustment on the upper portion of the control
board marked
"REVERSE
The level of sensitivity has to do with the weight of the gate and the condition of
installation.
Too sensitive = if the gate stops or reverses by itself.
Not sensitive enough = if the gate hits an object and does not stop or reverse.
Minimum
Sensitivity
Maximum
Sensitivity
There is an LED
"HEAVY
the operator. The operator will still function properly.
NOW YOUR INSTALLATION IS COMPLETE
B Y
S T E P
SENSOR".
Do Not Touch Alarm Sensor blue pot.
GATE" which will light up when the gate is heavier than normal for
I N S T A L L A T I O N