Table of input terminal functions 2
Function
Code
No.
34
F+SS3+AD2
Combination of forward run, preset-speed
command 3 and acceleration/deceleration 2
35
R+SS3+AD2
Combination of reverse run, preset-speed
command 3 and acceleration/deceleration 2
36
F+SS4+AD2
Combination of forward run, preset-speed
command 4 and acceleration/deceleration 2
37
R+SS4+AD2
Combination of reverse run, preset-speed
command 4 and acceleration/deceleration 2
38
FCHG
Frequency command forced switching
39
VF2
No.2 Switching of V/F setting
40
MOT2
No.2 motor switching
(VF2+AD2+OCS2)
41
UP
Frequency UP signal input from external contacts
42
DOWN
Frequency DOWN signal input from external
contacts
43
CLR
Frequency UP/DOWN cancellation signal input
from external contacts
44
CLR+RES
Combination of frequency UP/DOWN cancellation
and reset by means of external contacts
45
EXTN
Inversion of trip stop command from external
device
46
OH
Thermal trip stop signal input from external device
47
OHN
Inversion of thermal trip stop command from
external device
48
SC/LC
Forced switching from remote to local control
49
HD
Operation holding (stop of 3-wire operation)
50
CMTP
Forced switching of command mode and terminal
board command
51
CKWH
Display cancellation of the cumulative power
amount (kWh)
52
FORCE
Forced operation (factory configuration required)
53
FIRE
Fire-speed control
Note. When function 1, 10-12, 15-17, 38, 41-45 or 48 is assigned to an input terminal board, the input terminal
board is enabled even if the parameter command mode selection cmod is set at 1 (panel).
Function
ON: Simultaneous input from F, SS3 and AD2
ON: Simultaneous input from R, SS3 and AD2
ON: Simultaneous input from F, SS4 and AD2
ON: Simultaneous input from R, SS4 and AD2
ON:  (If  = )
OFF: 
ON: No.2 V/F setting
OFF: No.1 V/F setting
ON: No.2 motor
OFF: No.1 motor (Set value of , , ,
ON: Increase in frequency
ON: Reduction in frequency
OFF→ON: Resetting of UP/DOWN frequency by
ON: Simultaneous input from CLR and RES
OFF:  Trip stop
ON:  Trip stop
OFF:  Trip stop
Enabled when remote control is exercised
ON: Local control (setting of cmod,  and
)
OFF: Remote control
ON: F (forward run)/R: (reverse run) held, 3-wire
OFF: Slowdown stop
ON: Terminal board operation
OFF: Setting of 
ON: Monitor display cancellation of the cumulative
ON: Forced operation mode in which operation is
OFF: Normal operation
ON: Fire-speed operation (preset speed operation
OFF: Normal operation
71
E6581160
Action
(=0, , , , )
(Set value of , , , , )
(=0, , , , ,
, , , )
, , , , , )
means of external contacts