3.1.1
How to start and stop
[Example of a setting procedure]
Key operated
LED display
MODE
⇔
(1) Start and stop using the operation panel keys (=)
Use the
and
: Motor starts.
To switch between forward run and reverse run from the control panel, the parameter fr
(forward/reverse run selection) needs to be set to 2 or 3.
(2) RUN/STOP by means of an external signal to the terminal board (=):
Sink (Negative) logic
Use external signals to the inverter terminal board to start and stop the motor.
Short
and
CC
F
Open
and
F
CC
(3) Coast stop
The standard default setting is for slowdown stop. To
make a coast stop, assign a "1(ST)" terminal function
to an idle terminal using the programmable terminal
function.
Change to =.
For coast stop, open the ST-CC when stopping the
motor in the state described at left.The monitor on the
inverter at this time will display .
Displays the operation frequency (operation stopped).
(When standard monitor display selection = [Operation
frequency])
Displays the first basic parameter [History ()].
Press either the
Press ENTER key to display the parameter setting. (Default setting:).
Change the parameter to (terminal board) by pressing the
Press the ENTER key to save the changed parameter. and the
parameter set value are displayed alternately.
keys on the operation panel to start and stop the motor.
: Motor stops.
terminals: run forward
terminals: slow down and stop
23
Operation
or
key to select "".
Frequency
F-CC
Motor
speed
F-CC
ST-CC
E6581160
3
key.
Slow down
and stop
ON
OFF
Coast stop
ON
OFF
ON
OFF