Communication
Title
Function
No.
0307
Supply voltage
correction
(limitation of
output voltage)
0308
Dynamic braking
resistance
0309
Dynamic braking
resistor capacity
0311
Reverse-run
prohibition
0312
Random mode
0316
Carrier frequency
control mode
selection
0319
Regenerative
over-excitation
upper limit
0320
Droop gain
0323
Droop insensitive
torque band
0342
Braking mode
selection
0343
Release
frequency
0344
Release time
0345
Creeping
frequency
0346
Creeping time
0359
PID control
waiting time
0360
PID control
0362
Proportional gain
0363
Integral gain
0366
Differential gain
0396
Canceling mode
of stall prevention
*1 : Default values vary depending on the capacity. See the table of 68.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
-
0: Supply voltage uncorrected, output
voltage limited
1: Supply voltage corrected, output
voltage limited
2: Supply voltage uncorrected, output
voltage unlimited
3: Supply voltage corrected, output
voltage unlimited
Ω
0.1/0.1
1.0-3000
kW
0.01/0.01
0.01-30.00
-
-
0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
-
-
0: Disabled
1: Automatic setting
-
-
0: Carrier frequency not reduced
automatically
1: Carrier frequency reduced
automatically
2: Carrier frequency not reduced
automatically
Support for 500V/600V models
3: Carrier frequency reduced
automatically
Support for 500V/600V models
1/1
100 - 160
%
1/1
0-100
%
1/1
0-100
%
-
-
0: Disabled
1: Enabled (forward run)
2: Enabled (reverse run)
3: Enabled (operating direction)
Hz
0.1/0.01
-20.0
s
0.01/0.01
0.00-2.50
Hz
0.1/0.01
- 20.0
s
0.01/0.01
0.00-2.50
s
1/1
0-2400
-
-
0: Disabled, 1: Enabled
-
0.01/0.01
0.01-100.0
-
0.01/0.01
0.01-100.0
-
0.01/0.01
0.00-2.5
-
-
0: Setting acceleration time
1: Shortest acceleration time
61
E6581160
Default
User
Reference
setting
setting
E6581158
2
6.13.6
(WP, WN)
3 (AN)
* 1
6.13.4
* 1
6.13.4
0
6.13.7
0
6.12
1
6.12
140
6.13.5
0
6.14
10
6.14
0
6.15
3.0
0.05
3.0
0.10
0
6.16
0
0.30
0.20
0.00
0
6.19.2
7