Toshiba TOSVERT VF-S11 Instruction Manual page 71

Industrial inverter (for 3-phase induction motors)
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

Table of input terminal functions 1
Function
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
7
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Code
-
No function is assigned
ST
Standby terminal
F
Forward run command
R
Reverse run command
JOG
Jog run mode
AD2
Acceleration/deceleration 2 pattern selection
SS1
Preset-speed command 1
SS2
Preset-speed command 2
SS3
Preset-speed command 3
SS4
Preset-speed command 4
RES
Reset command
EXT
Trip stop command from external input device
CFMOD
Switching of command mode and frequency
setting mode
DB
DC braking command
PID
PID control prohibited
PWENE
Permission of parameter editing
ST+RES
Combination of standby and reset commands
ST+CFMOD
Combination of standby and command/frequency
setting mode switching
F+JOG
Combination of forward run and jog run
R+JOG
Combination of reverse run and jog run
F+AD2
Combination of forward run and
acceleration/deceleration 2
R+AD2
Combination of reverse run and
acceleration/deceleration 2
F+SS1
Combination of forward run and preset-speed
command 1
R+SS1
Combination of reverse run and preset-speed
command 1
F+SS2
Combination of forward run and preset-speed
command 2
R+SS2
Combination of reverse run and preset-speed
command 2
F+SS3
Combination of forward run and preset-speed
command 3
R+SS3
Combination of reverse run and preset-speed
command 3
F+SS4
Combination of forward run and preset-speed
command 4
R+SS4
Combination of reverse run and preset-speed
command 4
F+SS1+AD2
Combination of forward run, preset-speed
command 1 and acceleration/deceleration 2
R+SS1+AD2
Combination of reverse run, preset-speed
command 1 and acceleration/deceleration 2
F+SS2+AD2
Combination of forward run, preset-speed
command 2 and acceleration/deceleration 2
R+SS2+AD2
Combination of reverse run, preset-speed
command 2 and acceleration/deceleration 2
Function
Disabled
ON: Ready for operation
OFF: Coast stop (gate off)
ON: Forward run OFF: Slowdown stop
ON: Reverse run OFF: Slowdown stop
ON: Jog run, OFF: Jog run canceled
ON: Acceleration/deceleration 2
OFF: Acceleration/deceleration 1 or 3
Selection of 15-speed with SS1 to SS4 (4 bits)
ON: Acceptance of reset command
ON → OFF: Trip reset
ON:  Trip stop
ON: Forced switching from command mode to
ON: DC braking
ON: PID control prohibited
OFF: PID control permitted
ON: Parameter editing permitted
OFF: Parameter editing prohibited (If  = )
ON: Simultaneous input from ST and RES
ON: Simultaneous input from ST and CFMOD
ON: Simultaneous input from F and JOG
ON: Simultaneous input from R and JOG
ON: Simultaneous input from F and AD2
ON: Simultaneous input from R and AD2
ON: Simultaneous input from F and SS1
ON: Simultaneous input from R and SS1
ON: Simultaneous input from F and SS2
ON: Simultaneous input from R and SS2
ON: Simultaneous input from F and SS3
ON: Simultaneous input from R and SS3
ON: Simultaneous input from F and SS4
ON: Simultaneous input from R and SS4
ON: Simultaneous input from F, SS1 and AD2
ON: Simultaneous input from R, SS1 and AD2
ON: Simultaneous input from F, SS2 and AD2
ON: Simultaneous input from R, SS2 and AD2
70
E6581160
Action
terminal input mode, forced switching from
frequency setting mode to the mode
commanded between  and .
(If  = )