Horizontal Vent Termination Requirements; Vertical Vent Termination Requirements - FireplaceXtrordinair 36DV Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for 36DV:
Table of Contents

Advertisement

I
NSTALLATION
P
18
AGE
Horizontal Vent Termination Requirements (see the illustration below)
The horizontal vent termination (standard or snorkel) must meet the following requirements:
A Minimum 12" clearance to any door or window (9" in the U.S. if the window may not be opened)
B Minimum 12" above any grade, veranda, porch, deck or balcony
C Minimum 12" from outside corner walls
D Minimum 24" from inside corner walls
E Minimum 18" clearance below a soffit (eaves or overhangs) (24" for vinyl covered surfaces)
F Minimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides)
G Minimum 48" clearance from any adjacent building
H Minimum 84" clearance above any grade when adjacent to public walkways or driveways
NOTE: may not be used over a walkway or driveway shared by an adjacent building
I
Minimum 36" clearance from any mechanical air supply inlet, 72" for Canada
J
Minimum 12" clearance from the top and sides or 36" below any non-mechanical air supply inlet
K Minimum 36" from the area above the meter/regulator (vent outlet)
L Minimum 36" from the meter/regulator (vent outlet), 72" for Canada
Use the vinyl siding stand-off (#950) when installing on an exterior with vinyl siding.
Vent termination must not be located where it will become plugged by snow or other material
Vertical Vent Termination Requirements (see the illustration below)
The high-wind vertical termination is required (part # 991)
NOTE:
Our experience has shown that intermittent high winds can adversely affect the flame and
pilot of this appliance. The high-wind termination insures proper operation.