Listing Information; Safety Label - FireplaceXtrordinair 36DV Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for 36DV:
Table of Contents

Advertisement

The listing label is shown below. It can be found on the baseplate of the fireplace behind the access
door.
Warnock Hersey
Fireplace Xtrordinair 36DV
Listed Gas-Fired Direct Vent Wall Furnace
®
Tested to ANSI Z21.44-1992 "Gas-Fired Direct Vent Wall Furnace", CGA IR #41,
and CAN/CGA-2.17-M91 "Gas-Fired Appliances for use at High Altitudes"
Must be installed in accordance with all local codes, if any: if not, follow ANSI Z223.1-1992, NFPA 54(88),
the Manufactured Home Construction and Safety Standarad, Title 24 CFR, Part 3280, or the Canadian
CAN1-B149 Installation Code and the requirements listed in the accompanying owner's manual.
WARNING:
Use Simpson Dura-Vent direct vent system (model GS) to vent this appliance to the exterior (direct
discharge only without duct connection).
Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to the information in the owner's manual provided with this appliance. For assistance or
additional information consult a qualified installer, service agency or the gas supplier.
Risk of electrical shock. Switch the household breaker off or remove fuse before servicing unit.
Manufacture
1995
Jan.
Date:
1996
Feb.
1997
Mar.
Minimum Clearances to Combustibles
Faceplate to Adjacent Wall..................
Wood Floor..........................................
Back to enclosure (from stand-offs).....
Top to enclosure (from stand-offs).......
FAN TYPE VENTED CIRCULATOR
Blower Electrical Rating: 115 V., 1.5 Amps, 60 Hz, 150 watts
Input Rate on "HI" (BTU/Hr)*..................
Input Rate on "LO" (BTU/Hr)*................
Maximum Output (BTU/Hr)....................
Main Burner Orifice (DMS)*...................
*
In altitudes above 3,000 feet the vent configuration, orifice, or combination of both may need to be
changed. See the owner's manual for information on making these changes.
Apr.
Jul.
Oct.
May
Aug.
Nov.
Jun.
Sep.
Dec.
4-1/2"
0"
0"
0"
FOR USE WITH NATURAL GAS ONLY
40,000
31,000
32,800
#31
L
I
ISTING
NFORMATION
WH-
10850 117th Place N.E. - Kirkland, WA 98033
Sides to enclosure (from stand-offs)....
Faceplate to Mantel.............................
Flue Vent..............................................
Thermal Efficiency..............82% (blower on)
Output Capacity Rating...32,800 (blower on)
Minimum Inlet Pressure (inches W.C.).........
Maximum Inlet Pressure (inches W.C.)........
Manifold Pressure on HI (inches W.C.)........
Manifold Pressure on LO (inches W.C.).......
P
35
AGE
0"
24"
1"
5-1/2
7
3-1/2
1

Hide quick links: