Corner Installations; Raised Fireplaces; Facing Requirements - FireplaceXtrordinair 36DV Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for 36DV:
Table of Contents

Advertisement

I
NSTALLATION
P
8
AGE

Corner Installations

45° installations require the
following minimum framing
dimensions:

Raised Fireplaces

+ The fireplace (and
hearth if desired) may
be placed on a platform
designed to support the
fireplace (250 Lbs.) and
vent. The hearth
requirements stay the
same.

Facing Requirements

The non-combustible facing
must extend 10" above and
4-1/2" to each side of the
faceplate.
The fireplace requires 1/2" thick
concrete-board to extend from
the header to the floor and to the
framing members on both sides
(do not use sheetrock or
drywall).
The fireplace is shipped with a set-up face that is 1/16" larger on each side and top than the
faceplate. Use the set-up face as a template when installing the facing.
(C
.)
ONT
10-1/2"
46-1/4"
10"
4-1/2"
13-1/4"
Fireplace
(includes
1/2"
standoffs)
19-5/8"
43"
65-1/4"
11-1/8"
Cement-board must
extend from the header
to the floor and to the
framing members on
both sides.
Non-combustible
Facing
Keep the set-up face
on the fireplace when
installing the facing.