Communication conditions (Factory default)
Signal level
Sync. method
Baud rate
Parity
Character length
Stop bit
X parameter
S parameter
Basic format
Transmission from the computer starts with STX, then the ID, command, parameter, and ETX are sent in this order. Add parameters according
to the details of control.
ZZ, 01 to 64 and 0A to 0Z
(2 bytes)
Start (1 byte)
Basic format (has subcommands)
Sub command (5 bytes)
*1 When transmitting a command which does not need a parameter, an operation (E) and parameter are not necessary.
Attention
f If a command is transmitted after the lamp starts illuminating, there may be a delay in response or the command may not be executed. Try
sending or receiving any command after 60 seconds.
f When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response from the projector before
sending the next command. When transmitting a command which does not need a parameter, a colon (:) is not necessary.
Note
f If a command cannot be executed, the "ER401" response is sent from the projector to the computer.
f If an invalid parameter is sent, the "ER402" response is sent from the projector to the computer.
f ID transmission in RS-232C supports ZZ (ALL) and 01 to 64, as well as 0A to 0Z groups.
f If a command is sent with a specified ID, a response will be sent to the computer only in the following cases.
g It matches the projector ID
g ID setting is set to ALL and [RESPONSE(ID ALL)] is [ON]
g ID setting is set to GROUP and [RESPONSE(ID GROUP)] is [ON]
f STX and ETX are character codes. STX shown in hexadecimal is 02, and ETX shown in hexadecimal is 03.
162 - ENGLISH
Chapter 6 Appendix — Technical information
RS-232C-compliant
Asynchronous
9 600 bps
None
8 bits
1 bit
None
None
ID designate
3 command characters (3 bytes)
Semi-colon (1 byte)
2 ID characters (2 bytes)
Operation (1 byte)
"=" (Set the value specified using parameter)
Parameter (undefined length)
Colon (1 byte)
Same as the basic format
Parameter (6 bytes)
*1
Symbol "+" or "–" (1 byte) and setting or adjustment value (5
bytes)
*1
End (1 byte)