4 Calculate the TAGADJUST value by multiplying the distance
To set TAGADJUST using a Fingerprint command
•
To set TAGADJUST using an IPL command
•
EasyCoder Printer (PM4i, PX4i, and PX6i ) RFID User's Guide
Printhead
Antenna
TAGADJUST Distance for PX4i and PX6i IPL Printers
you measured in the previous Step 3 by the Thermal
Printhead Resolution (in dots per millimeter):
TAGADJUST (dots) = DISTANCE (mm) x TPHR (dots/mm)
where:
≈ 203 ≈ 8.0 dots/mm
TPHR
203dpi
25.4
≈ 300 ≈ 11.8 dots/mm
TPHR
300dpi
25.4
≈ 406 ≈ 16 dots/mm
TPHR
406dpi
25.4
If the distance is measured in inches:
TAGADJUST (dots) = DISTANCE (in) x TPHR (dots/in)
Send this command to your printer.
SETUP "RFID,TAGADJUST,<value>".
Send this command to your printer.
<SI>J1,<VALUE>