I0600 SERIES

I0600A
Self-Contained Air-Cooled Model
Characteristics vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
70/21
80/27
90/32
100/38
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Entering
Condenser °F/°C
70/21
80/27
90/32
100/38
1 Based on average ice slab weight of 4.12 - 4.75 lb.
OPERATING PRESSURES
Air Temp
Entering
Condenser
°F/°C
50/10
70/21
80/27
90/32
100/38
110/43
1 Suction pressure drops gradually throughout the freeze cycle
Part Number Preliminary 6/11
Water Temperature °F/°C
50/10.0
7.6-9.0
8.8-10.4
9.7-11.4
11.1-13.1
Freeze Cycle
Discharge
Suction
Pressure
Pressure
PSIG
220-255
220-270
230-300
265-345
300-395
340-430
Freeze Time
70/21.1
9.5-11.2
9.9-11.7
11.0-12.9
12.3-14.4
Water Temperature °F/°C
50/10.0
70/21.1
650
575
530
470
Discharge
Pressure
PSIG
45-27
140-160
45-28
145-170
50-30
165-185
54-32
180-215
60-35
210-245
65-39
240-280
Harvest
90/32.2
10.2-12.0
10.5-12.3
11.4-13.4
12.8-15.0
90/32.2
540
520
475
430
Harvest Cycle
Suction
Pressure
PSIG
PSIG
60-80
70-90
75-95
80-105
85-120
100-140
1
Time
1-2.5
1
505
495
460
415
1