Problem
Too noisy
Data incorrect
or unreliable
with equipment
running
Problems in
monitoring
heart rate with
the chest band
32
Bike Forma - User's manual
Cause
Equipment not properly
levelled.
Damaged bearings.
Worn belt.
Blocked key on keypad.
Equipment next to source
of radio interference (e.g.
electrical domestic
appliances).
An internal connector has
become accidentally
disconnected.
Internal contact in control
panel.
Other transmitters situated
nearby.
Strong interference sources
nearby.
Remedy
Check the position and
level the adjustment feet.
Contact the Technogym
Technical Support Service.
Contact the Technogym
Technical Support Service.
If the problem persists,
contact the Technogym
Technical Support Service.
Move the equipment to
another place or move the
domestic appliances.
Contact the Technogym
Technical Support Service.
Contact the Technogym
Technical Support Service.
Move the equipment far
enough away to stop signal
interference (minimum
distance between two units
80 cm).
Find the interference source
(e.g. an electrical domestic
appliance) and move it away,
or move the equipment.