Clearances Figure & Table - Schwank STS-JZ Installation & Owner's Manual

Low intensity tube type infrared heaters
Table of Contents

Advertisement

FIGURE 1 MINIMUM CLEARANCES TO COMBUSTIBLES* - refer to Table 1 for values
NOTE: A 'PEEL & STICK' SIGN IS SUPPLIED: USE AN INDELIBLE MARKER TO
ENTER VALUES 'H', 'S', 'F', & 'B' ON .
POST THE SIGN ADJACENT TO THE HEATER THERMOSTAT OR IN A
PROMINENT LOCATION.
Suspended at an
angle up to 45°
F
M a x i m u m
Stack Height
H = T- C
T
'T'
is
meas-
ured on site,
FLOOR
TABLE 1 MINIMUM CLEARANCES TO COMBUSTIBLES*
MODEL
inches (cm)
STS-JZ / IQ 200 13 (33)
STS-JZ / IQ 175 12 (31)
STS-JZ / IQ 155 5.5 (14)
STS-JZ / IQ 130 4.5 (11)
STS-JZ / IQ 110 3.5 (9)
STS-JZ / IQ 100 6.5 (16.5)
STS-JZ / IQ 80 3
STS-JZ / IQ 60 2.5 (6)
STS-JZ / IQ 45 2.75 (7)
*The clearance to combustible materials represents the minimum distance that must be main-
tained between the heater and a nearby surface. The stated clearance to combustibles
represents a surface temperature of 90F° (50C°) above room temperature. .
See next page for details.
D
B
C
H
SUSPENDED AT AN ANGLE
UP TO 45 DEGREES
D
B
inches (cm)
inches (cm)
74 (188)
6 (15.2)
72 (183)
6 (15.2)
44 (112)
1 (2.5)
1 (2.5)
35 (89)
1 (2.5)
26 (66)
57 (145)
1 (2.5)
(8)
1 (2.5)
23 (59)
1 (2.5)
17 (43)
1 (2.5)
24 (61)
A
S
C
H
FLOOR
F
C
inches (cm)
inches (cm)
70 (178)
14 (36)
68 (172)
13 (33)
64 (163)
3.5 (9)
60 (152)
3.3 (9)
54 (137)
2 (5)
68 (172)
6 (15)
38 (97)
1.75 (5)
34 (86)
1.5 (4)
32 (81)
2.25 (6)
7
Suspended
horizontally
S
M a x i m u m
Stack Height
H = T- C
T
'T'
is
meas-
ured on site,
SUSPENDED
HORIZONTALLY
A
S
inches (cm)
44 (112)
42 (107)
19 (48)
11 (28)
10 (25)
22 (56)
6 (15)
5.5 (14)
7 (18)
STS-JZ-F / IQ-F I&O Manual
C
inches (cm)
76 (193)
74 (188)
64 (163)
60 (152)
54 (137)
68 (172)
38 (97)
34 (86)
32 (81)
IM101220
RD: MAY 2014
RL: 17A