Schwank STS-JZ Installation & Owner's Manual page 49

Low intensity tube type infrared heaters
Table of Contents

Advertisement

FIGURE 25 HANGER SPACING / AIR INTAKE TO VENT LENGTH
*

POSITION BURNER END HANGER 6.5 INCHES (17 CM) FROM BURNER [2.5 INCHES (6.4 CM)
FROM TUBE FLANGE]

POSITION SYSTEM HANGERS 116 INCHES (295 CM) APART
* ANGLE BURNER SUPPORT CHAIN BACK OVER BURNER - ALLOWS TUBE SYSTEM EXPANSION
Tube
Length
'L' = center air intake to end
10'
11'-3 3/4"
20'
20'-11 3/4" ; 251 3/4"
30'
30'-7 3/4"
40'
40'-3 3/4"
FIGURE 26 HANGER / REFLECTOR ORIENTATION HORIZONTAL TO 45
; 135 3/4"
;
345 cm
;
628 cm
; 367 3/4"
;
934 cm
; 483 3/4"
; 1229 cm
Tube
Length
'L' = center air intake to end
50'
49'-11 3/4" ; 599 3/4"
60'
59'-7 3/4"
70'
69'-3 3/4"
49
; 1523 cm
; 715 3/4"
; 1818 cm
; 831 3/4"
; 2113 cm
0
STS-JZ-F / IQ-F I&O Manual
IM101220
RD: MAY 2014
RL: 17A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq

Table of Contents