Technical Specification Ambient, no heat - (IP21) Model Output Airflow*1 Sound power*2 Sound Pressure Motor Voltage Amperage Weight (MBH) (CFM) (dB(A)) (dB(A)) power (W) motor (V) motor (A) (lb) AC-VA36-23 1400 208V1~ AC-VA60-23 1950 208V1~ AC-VA72-23 2800 1000 208V1~ AC-VA96-23 3300 1173 208V1~...
Page 3
Outlet air temperature: +95 °F 1. Recommended outlet air temperature for good comfort and optimized output. 2. Nominal output at given supply and return water temperature. Air Curtain Select14 Series Electric Heated Nominal Length of unit in inch Voltage Code 600V...
Page 4
The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Les pages de présentation contiennent principalement des images. Pour la traduction des textes en anglais, consultez la page correspondante à la langue souhaitée.
Page 5
Dimensions Valve (3/4"), outside thread A / B / C / D 72" & 96" Models Mounting bracket E / F 3.3 ft: 4 x M8 Controller 4.9 ft: 4 x M8 6.6 ft: 6 x M8 8.2 ft: 6-8 x M8 (inch) Model (inch)
Page 6
Fig. 1A: Open the unit by raising the front panel. The front is Fig. 1B: When the front has been removed it it important to blocked in open position with the front hatch hook. be sure it is firmly seated in the front locks again. Controller Fig.
All Models: 36” & 60” D / E (inch) Model (inch) Model 5.08 All Models All Models 4.08 All Models All Models All Models All Models AC-VA36-23 29.8 AC-VA96-23 AC-VE36-20(48)(60) 29.8 AC-VE96-48(60) AC-VW36-23 29.8 AC-VW96-23 50.4 AC-VA60-23 30.8 AC-VA96-23 50.4 AC-VE60-20(48)(60) 30.8 AC-VE96-48(60)
Page 10
Accessories Nozzle Extensions Model Models JC-0725-10 All 36” Models JC-0725-15 All 60” Models JC-0725-20 All 72” Models JC-0725-25 All 96” Models Fig. 10 JC-0712-XX Single Piece Design Kit Ceiling Design Kit Ceiling Model Length Kit Height (inch) (ft) JC-0712-10 8.00-12.00 0.6-1.0 JC-0712-15 12.00-20.00...
Page 11
Accessories NOTE: The air curtain must be secured in the wall or ceiling. JC-0724-XX Vertical (Floor) Mounting Kit • Used to adapt a horizontal unit for vertical installation. • Includes floor frame and mounting parts to support the top. • Vertical kit allows two units to be installed on top of each other.
Accessories JC-0745-XX JC-0749-XX - Select14 Series Return Water Temp. Sensor Controller - Ambient Models JC-0750-XX - Select14 Series Controller - Heated Models JC-0732 JC-0742-XX RJ12 Cable next to JC-0732-XX Temperature Sensor (Different Lengths Available) JC-0751-XX - 3/4 Plumbing Kit Includes: •...
Page 13
Wiring Diagram - Schwank Select14 Series Air Curtain Ambient & Water Heated All Ambient & Water Heated AC-VA36/VW36 Models [except 36"] Air Curtain PCB Trafo PE L1 L2 208V1~ schwankgroup.com/schwankair...
Page 14
Wiring Diagram - Schwank Select14 Series Air Curtain - 36” & 60” Electric Heated 208V Actuator 230VSupply 230V Room schwankgroup.com/schwankair...
Page 15
Wiring Diagram - Schwank Select14 Series Air Curtain - 72” & 96” Electric Heated 208V Supply 2 30V Room schwankgroup.com/schwankair...
Page 16
Wiring Diagram - Schwank Select14 Series Air Curtain - 36” & 60” Electric Heated 600V A ctuato r 230V S upply 230V R oom schwankgroup.com/schwankair...
Page 17
Wiring Diagram - Schwank Select14 Series Air Curtain - 72” & 96” Electric Heated 480V/600V Actuator 230VSupply 230V Room schwankgroup.com/schwankair...
Replacement Parts List Schwank Select14 Series Air Curtain - Ambient schwankgroup.com/schwankair schwankgroup.com/schwankair...
Page 19
Model # Select14 Series Air Curtain Screws (Surface) JC-0601-XX AC-VA36-23 AC-VA60-23 AC-VA72-23 AC-VA96-23 Select14 Series Air Curtain Front Cover 36” (Surface) JC-0602-10 AC-VA36-23 Select14 Series Air Curtain Front Cover 60” (Surface) JC-0602-15 AC-VA60-23 Select14 Series Air Curtain Front Cover 72” (Surface)
Page 20
Replacement Parts List Schwank Select14 Series Air Curtain - Electric schwankgroup.com/schwankair...
Page 21
AC-VE36-60 Select14 Series Air Curtain Heating Rod - 600V 60” JC-0617-15 AC-VE60-60 Select14 Series Air Curtain Heating Rod - 600V 60” JC-0617-15 AC-VE72-60 Select14 Series Air Curtain Thermal Cut Off Electric Heated (Surface) JC-0618-XX AC-VE36-20 AC-VE36-48 AC-VE36-60 AC-VE60-20 AC-VE60-48 schwankgroup.com/schwankair...
Page 22
Item Description Part # Model # AC-VE60-60 AC-VE72-20 AC-VE72-48 AC-VE72-60 AC-VE96-48 AC-VE96-60 Select14 Series Air Curtain Sensor Casing (Surface) JC-0619-XX AC-VE36-20 AC-VE36-48 AC-VE36-60 AC-VE60-20 AC-VE60-48 AC-VE60-60 AC-VE72-20 AC-VE72-48 AC-VE72-60 AC-VE96-48 AC-VE96-60 Internal Temp Sensor for Smart Controller JC-0620-XX AC-VE36-20 AC-VE36-48...
Page 23
Item Description Part # Model # Select14 Series Air Curtain Discharge Nozzle 60” JC-0606-20 AC-VE72-60 Select14 Series Air Curtain Discharge Nozzle 96” JC-0606-25 AC-VE96-48 Select14 Series Air Curtain Discharge Nozzle 96” JC-0606-25 AC-VE96-60 Select14 Series Air Curtain Nozzle Holder JC-0607-XX...
Page 24
Replacement Parts List Schwank Select14 Series Air Curtain - Hydronic schwankgroup.com/schwankair...
Page 25
Model # Select14 Series Air Curtain Screws (Surface) JC-0601-XX AC-VW36-23 AC-VW60-23 AC-VW72-23 AC-VW96-23 Select14 Series Air Curtain Front Cover 36” (Surface) JC-0602-10 AC-VW36-23 Select14 Series Air Curtain Front Cover 60” (Surface) JC-0602-15 AC-VW60-23 Select14 Series Air Curtain Front Cover 72” (Surface)
Page 26
• Read the safety instructions before performing installation and/or maintenance activities on the unit. • Installation and/or maintenance activities on the unit may only be performed by qualified technical staff. • The unit shall not be installed and used outdoors or in environments that are aggressive, or potentially explosive.
Application area both wall and ceiling installations, se accessories Select14 Series Air Curtain is developed to fit all pages. entrances. Recommended installation height up to 14 ft. The air curtain is available without heat, Mounting with wall brackets with electrical heating and with water heating.
Vertical mounting JC-0724-XX Note! If you want to divide the output between two connection Units from 4.9 feet and longer may be used points, the series cabling must first vertically. For vertical mounting, all units must be removed (72" & 96" Electric be supplemented with a vertical kit containing Heated, 2x480V3~/600V3~).
Filter (VW) The connections to the heating coil must be equipped with shut off valves (included in The water coil is protected against dirt and SchwankAir valve kits) to allow problem free blockage by an air filter which covers the coil removal.
Overheating Troubleshooting The air curtain unit with electrical heating is If the fans are not working or do not blow properly, equipped with an overheat protection. If it is check the following: deployed due to overheating, reset as follows: • That the intake grille/filter is not dirty.
Page 31
Packaging Safety Packaging materials are chosen with • For all installations of electrically heated consideration to the environment and are products a residual current circuit breaker 300 therefore recyclable. mA for fire protection should be used. • Keep the areas around the air intake and Handling of product at end of working life exhaust grilles free from possible obstructions! •...
Consignes de montage et mode d'emploi Généralités Montage horizontal Lisez attentivement les présentes consignes Le rideau d'air est monté horizontalement, avec avant d'installer et d'utiliser l'appareil. Conservez la grille de sortie vers le bas aussi près que possible ce manuel afin de pouvoir le consulter de la porte.
Montage vertical JC-0724-XX Appareil avec chauffage électrique Le raccordement électrique s'effectue sur la Les appareils mesurant 4.9 pieds et plus peuvent partie supérieure de l'appareil. Voir Fig.2. 208V3~/ être utilisés à la verticale. Pour pouvoir être 480V3~/ 600V3~ commande et puissance (*1 *2) montés verticalement, tous les appareils doivent doivent être connectées aux borniers dans la être équipés d'un kit de montage vertical...
Page 34
Réglage initial de la vitesse de ventilation La batterie à eau chaude ne doit pas être branchée sur un circuit hydraulique à pression La vitesse de ventilation lorsque la porte s'ouvre standard, ni sur un circuit ouvert. est réglée à l'aide de la commande. Garder à Noter que l'appareil doit être précédé...
Remplacement d'un ventilateur 1. Déconnecter l'alimentation électrique. 2. Desserrer les vis et soulever la face avant. La 1. Déterminer quel ventilateur ne fonctionne pas. face est bloquée en position ouverte à l'aide du 2. Débrancher ses câbles d'alimentation. crochet de la trappe avant. Voir Fig. 1A. 3.
Page 36
Sécurité Pour les appareils à batterie à eau chaude, contrôler également les points suivants : • Un disjoncteur à courant résiduel de 300 mA • Purge de la batterie à eau chaude. doit être utilisé contre les risques d'incendie • Débit d'eau suffisant. dans les installations de produits avec •...
Traduction des pages de présentation Filetage extérieur • Outside thread Quantité inclue • Quantity included Pièces • Accessoires • Accessories Voir le manuel de la référence XXX. • See separate manual for xxx Schémas de raccordement pour xxx et xxx, voir le •...
Page 38
Tableaux de dimensionnement • Supply water temperature Température de l'eau d'alimentation • Room temperature Température ambiante • Outlet air temperature*1 Température de l'air de sortie • Water temperature Température de l'eau • Fan position Position ventilateur • Airflow Débit d'air •...
Page 39
LIMITED WARRANTY CERTIFICATE Warranty Schwank Air Curtain Select14 Series Air Curtains The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to the terms of this document. Five Year Limited Warranty Subject to the conditions and limitations stated herein, during the term of this limited warranty, we will supply any component part (at our option a new or repaired component part) of the air curtain as defined below, which the Manufacturer’s exami-...
Page 40
Schwank Air Curtains 1-877-686-3779 (toll-free) 1-706-554-6191 csr@schwankgroup.com schwankgroup.com/schwankair Canada 2 Schwank Way, 5285 Bradco Blvd., Waynesboro, GA Mississauga, ON 30830 L4W 2A6 schwankgroup.com/schwankair...
Need help?
Do you have a question about the Select14 Series and is the answer not in the manual?
Questions and answers