5) Please NOTE that each hanger has a 'flat' side and a 'cavity' side – FIGURE 6
a) Starting at the burner end of the heater: all hangers (except the last plate hanger) are
oriented with the cavity side of the hanger facing toward the burner end
b) Only the cavity side of the vent end plate hanger faces the vent - FIGURE 6
Refer to Figures on next pages, then proceed to Section 9. Burner and Tube Installation
FIGURE 6 END PLATE & WEBBED HANGERS
Use solid End Plate Hanger
FIGURE 7 TYPICAL HANGER & SUPPORT SPACING
8.5" (21.6 cm)
Angle the burner suspension
chain back over the burner to
allow system expansion
STS-JZ-F / IQ-F I&O Manual
IM101220
RD: MAY 2014
RL: 17A
at Burner and Vent ends
(note cavity side faces
outward from tube)
4.5" (21.6 cm) IMPORTANT
116" (295 cm)
10
The distance between the
tube flange and face of
the plate hanger must be
4.5" (11.4 cm)
Intermediate Webbed
Hanger (note: cavity side
always faces Burner).
116" (295 cm)
1. Burner Assembly
2. Flange Adapter
3. Flanged Tube
4. Swaged Tube
5. Vent termination
6. End Plate Hanger
7. Webbed Hanger
8. Hanging Chains
9. Focus Shield Reflector
10. Reflector Stabilizer