R
10
Maintaining & Servicing Your Appliance
A. Proper Shutdown Procedure
1. Set wall control to OFF on AUTOMATIC / MANUAL SET-
TING screen. Figure 35.1.
2. Wall control screen will scroll through the following mes-
sages after setting to OFF.
• Shutdown
• Auto-Clean
• Off
3. Smoke spillage into the room can occur if the appliance
is not cool before unplugging.
4. There is a risk of shock if the appliance is not unplugged
before servicing the appliance.
After servicing, restart with the AUTO/MANUAL SETTINGS
screen. Figure 35.1.
B. Quick Reference Maintenance Chart
Cleaning or Inspection
Ash Pan - Burning Wood Pellets
Ash Pan - Burning Alternate Fuels
Ash Removal from Firebox
Auto-Clean Inspection
Blower, Combustion (Exhaust)
Blower, Convection
Door Latch Inspection
Firebox - Prepare for Non-Burn Season At end of heating season
Firepot - Burning Softwood Pellets
Firepot - Burning Hardwood Pellets
Firepot - Burning Alternate Fuels
Glass
Heat Exchanger & Drop Tube
Hopper
Venting System
NOTICE: These are recommendations. Clean more frequently if you encounter heavy
build-up of ash at the recommended interval or you see soot coming from the
vent. Not properly cleaning your appliance on a regular basis will void your
warranty.
August 27, 2009
Frequency
Every 5 bags of fuel
Every 1 bag of fuel
More frequently depending on the
fuel type or ash build-up
More frequently depending on the
fuel type
More frequently depending on the
fuel type
More frequently depending on the
fuel type
Prior to heating season
Every 5 bags
Every 3 bags
Every 1 bag
When clear view of fi repot
becomes obscured
Every 1 ton of fuel
Every 1 ton of fuel or when chang-
ing fuel types
More frequently depending on the
fuel type
7036-135F
Mt. Vernon Pellet Insert (AE)
Before Servicing Your Appliance
CAUTION! SHOCK AND SMOKE HAZARD!
• Proper Shutdown Procedure must be followed.
• Smoke spillage into room can occur if appliance is not
cool before unplugging appliance.
• Risk of shock if appliance is not turned off before servic-
ing appliance.
Automatic
Manual
Off
Figure 35.1
Follow the detailed instructions found in this
section for each step listed in the chart below.
Daily Weekly Every 2
OR
X
OR
X
OR
X
OR
OR
OR
OR
OR
OR
X
OR
X
OR
X
OR
X
OR
OR
OR
Monthly
Yearly
Weeks
X
X
X
X
X
X
X
X