2. Specify a suitable value for each item.
Item
Trigger
I/O1
setting
I/O
MD
Audio IN
Note:
I/O1, I/O, MD, Audio IN can be selected at the same time as a trigger.
To use as an event trigger, turn ON the check box and
set the make/break status for an operation of input signal
1 to be detected.
Note:
The make/break status detects the following signal
operation.
make
break
If I/O1 is specified as a trigger, I/O1 cannot be used for
signal output.
I/O1 works as an input port for IR TRG operation if the
IR is set to [Trg] for the TOP image, in which case no
event trigger settings are possible.
To use as an event trigger, turn ON the check box and
set the make/break status for an operation of input signal
 to be detected.
Note:
The make/break status detects the following signal
operation.
make
break
If I/O is specified as a trigger, I/O cannot be used for
signal output.
To detect a motion, turn ON the check box.
*MD: Motion Detection
MD
Set the ON/OFF status of the frame display for the
display
subject.
MD
Set the detection sensitivity (0 to 9).
Sensitivity
Dwell time Set the dwell time of motion detection (0 to 9).
To detect a sound, turn ON the check box and set the
microphone sensitivity (0 to 5).
Details
Active LOW
Active HIGH
Active LOW
Active HIGH
Setting up Image