Loctite 1390322 Operation Manual

Loctite 1390322 Operation Manual

Integrated semi-automatic dispenser dual channel with low level sensor

Advertisement

Loctite
Integrated Semi-Automatic Dispenser
Dual Channel with Low Level Sensor
Part Numbers
1390322,
1390321,
0 – 1 Bar
0 – 7 Bar
EQUIPMENT
Operation Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Loctite 1390322

  • Page 1 EQUIPMENT Operation Manual  Loctite Integrated Semi-Automatic Dispenser Dual Channel with Low Level Sensor Part Numbers 1390322, 0 – 1 Bar 1390321, 0 – 7 Bar...
  • Page 2: Table Of Contents

    Table of Contents PLEASE OBSERVE THE FOLLOWING..................... 3 ..........................3 MPHASIZED ECTIONS DESCRIPTION ..............................3 ..............................3 PERATION ............................5 TEMS UPPLIED ..........................6 VERALL IMENSIONS & B ).................. 7 ONTROL ANEL RONT ACK OF ONTROLLER TECHNICAL DATA............................8 ............................8 PECIFICATIONS INSTALLATION..............................
  • Page 3: Please Observe The Following

    The system is also equipped with low level sensor which can notify the operator that the adhesive package needs to be replaced. The Integrated Semi-Automatic Dispenser 1390322 is equipped with a precision pressure regulator 0-1 bar (0-14 PSI).
  • Page 4 It regulates the adjusted dispensing pressure and controls the dispensing during the selected dispensing time. ® An uncovered bottle of LOCTITE product is placed directly into the integrated reservoir, the tube is inserted into the product, and the reservoir lid is clamped in place.
  • Page 5: Items Supplied

    Pay attention if cyanoacrylate is dispensed – Air in the feed line results in curing of the product! Items Supplied Integrated Semi-Automatic Dispenser, Dual Channel, 0-1 Bar, Order No. 1390322 or Integrated Semi-Automatic Dispenser, Dual Channel, 0-7 Bar, Order No. 1390321...
  • Page 6: Overall Dimensions

    Overall Dimensions...
  • Page 7: Control Panel (Front & Back Of Controller)

    Control Panel (Front & Back of Controller) Reservoir Fitting Air Pressure On/Off Switch Valve Pressure Relief Tank Pressure Regulator Display Channel A On Output Mode Switch Channel A Off Output Right Arrow Switch Channel B On Output Manual Switch for Channel A Channel B Off Output Low Level Error LED Light XS1 Channel A (Master)
  • Page 8: Technical Data

    - 10°C to + 60°C (+14°F to +140°F) ® If the required air quality is not achieved, install a Loctite filter regulator. In the US order a 5 m filter using part number 985397. In Europe or Asia, order a 10 m filter...
  • Page 9: Installation

    Refer to the list of supplied parts (see page 4) and compare to the contents. Report any missing or damaged parts promptly. In North America contact 1-800-LOCTITE (562-8483) and for all other locations contact your local Henkel customer service.
  • Page 10: Operation

    Operation Function of the Control Panel: Switch (4): Switching different mode as below cycle: Run: Auto > Run: Manual > Run: Continuous > Set: Time (Auto) > Set: Delay (Auto) > Set: Output > Set: Low Level > Set: Lock-Out Switch (8) Set the data in all “SET: XXXX”...
  • Page 11: Xs1 Connection Signal

    XS1 Connection Signal: The system can be auto detecting when the footswitch(s) plug onto the system. Only XS1 Channel A (Master) Footswitch plugged: The footswitch can control both output of Channel A and Channel B and start at the same time. Only XS1 Channel B Footswitch plugged: The footswitch can only control the output of Channel B.
  • Page 12: Run: Continuous Mode

    Run: Continuous Mode Engage the footswitch(s) to start dispensing and hold until the dispensing cycle is complete. When the footswitch is released, the dispensing will end immediately. The display on the system will show the last dispensing time. If needed, press to store the dispensing time to “Run: Auto”...
  • Page 13: 5.10 Set: Low Level Mode

    5.10 Set: Low Level Mode Press , the setting for Low Level mode start to flash. Press for switching between “OFF”, “LAMP” and “LAMP + STOP”. After completed setting, press to save and exit. Notice: OFF: Only digital output from XS1 LAMP: Digital output from XS1 + LED Light on control panel LAMP + STOP: Digital output from XS1 + LED Light on control panel + System Stop Notice:...
  • Page 14: Troubleshooting

    Troubleshooting Symptom Possible Causes Corrections  Check the power voltage. The digital display - No power voltage present. does not light. - Powers switch 12 in position O (OFF).  Switch power switch to position I (ON). - Power adaptor with cord is defective. ...
  • Page 15: Care And Maintenance

    Clean, dry, filtered air must be used. If it is not, the solenoids on the controller will be fouled over time. ® Notice: If the required air quality is not achieved, install a Loctite filter regulator. In the US order a 5 m filter using Part Number 985397. In Europe or Asia, order a 10 m filter...
  • Page 16: Documentation

    Documentation Electrical Schematic FILM SWITCH MAIN PCB MAIN POWER SWITCH SOLENOID VALVE B START SWITCH SECONDARY PCB START SWITCH XS1 MASTER SOLENOID VALVE A POWER INPUT JACK LOW LEVEL SENSOR...
  • Page 18: Pin Connections

    Pin Connections XS1 Start via Footswitch, additional Empty Signal and Ready Signal. Warning! Never connect external voltage on pin 1 or pin 9! NEVER short pins 3 and 4, nor 6 and 7 together, permanent board damage will result.
  • Page 19: Accessories, Spare Parts & System Components Sold Separately

    Accessories, Spare Parts & System Components Sold Separately Loctite Item Number Description Accessories ® 985397 Loctite Air Filter, Regulator, Gauge Spare Parts 8900064 Reservoir Tank Fitting, ¼ inch NPT x ¼ inch Tubing 97201 Footswitch 97972 ¼ inch O.D. Black PE Teflon Lined Fluid Feed line Tubing (33 feet length)