Operating Manual
VoluDrop Dispenser UV
97650

Advertisement

Table of Contents
loading

Summary of Contents for Loctite VoluDrop UV 97650

  • Page 1 Operating Manual VoluDrop Dispenser UV 97650...
  • Page 2 Contents English ........................3 - 16...
  • Page 3: Table Of Contents

    Contents Please observe the following ..................4 Emphasized Sections.....................4 Items Supplied........................4 For Your Safety ......................5 Field of Application (Intended Usage) ................5 Description........................6 Theory of Operation .......................6 Operating Elements and Connections................6 Technical Data ......................7 Installation ........................8 Connecting to the Product Reservoir ................8 Connecting to the Controller...................8 Selection of the Required Dispensing Needle..............10 Dispensing ........................11...
  • Page 4: Please Observe The Following

    Please observe the following Emphasized Sections Warning! Refers to safety regulations and requires safety measures that protect the operator or other persons from injury or danger to life. Caution! Emphasizes what must be done or avoided so that the unit or other property is not damaged.
  • Page 5: For Your Safety

    The free end of the product feedline is connected to the product reservoir. For product reservoirs, 0.5 l and 2 l versions are available. The control of the dispenser is provided by a control unit of the LOCTITE equipment line.
  • Page 6: Description

    Description Theory of Operation The LOCTITE adhesive is transported through a product feedline to the dispenser by the dispensing pressure in the product reservoir. This feedline has a PTFE-liner to prevent curing of adhesives in this area. When the ejector piston moves back the dispensing chamber will be filled. The adhesive is spat under high pressure by very fast movement of the piston.
  • Page 7: Technical Data

    Pneumatic supply min. 6 bar (87 psi) Quality Filtered 10 µm, oil-free, non-condensing If required quality is not achieved, install a LOCTITE filter regulator Accessory Order No. 97120 Pneumatic hose size, control air External dia. 4 mm calibrated; connection Internal dia. 2.5 mm...
  • Page 8: Installation

    Installation – Keep the pressure hose as short as possible. Short switch-on and switch-off times for the dispenser are within reach. – Keep product feedlines as short as possible. The shorter the feedline the smaller the specific resistance and the lower the dispensing pressure can be. –...
  • Page 9 Installation 97103/97204 97123 P in 6- 8 ba r ca t. no . 97 12 Lo ct in Ge rm an Ta lla W hit gh t (I re Bu sin la nd Ta lla es to ) Lt gh t, es s Pa rk bli n...
  • Page 10: Selection Of The Required Dispensing Needle

    – PTFE-lined stainless steel needles (especially for fast curing products). As a matter of principle, spitting is possible with each LOCTITE dispensing needle. An exact spitting is only possible with the conical dispensing needles. With same dispensing quantity certain correlation determines the selection of the needle.
  • Page 11: Dispensing

    2. If it is not available an additionally pressure multiplicator has to be used. To limit the pressure at 8 bar a LOCTITE filter regulator order no. 97120 or a comparable one is necessary. Otherwise the integrated burst plate of the reservoir can burst (lower burst limit 8.8 bar / 125 psi).
  • Page 12: Adjusting The Dispensing Quantity

    Dispensing Adjusting the Dispensing Quantity The dispensed quantity is adjusted by setting the size of the dispensing chamber in the dispenser. • Adjust the required amount of adhesive by turning the stroke adjustment knob 7 clockwise or counter-clockwise to decrease or increase the effective size of the chamber.
  • Page 13: Maintenance

    Maintenance The VoluDrop Dispenser requires no special care. As maintenance only a sealing ring inside has to be replaced regularly. The dispenser has to be cleaned, if it is dismantled for replacing the sealing rings, see section 5.1. The maintenance interval is at a dispensing rate of : –...
  • Page 14: Troubleshooting

    • Replace the product feedline and/or – Curing in the product feedline or in the dispensing needle. the dispensing needle. • Loctite Service – Curing in the VoluDrop Dispenser. • Check the controller setting (see – Controller incorrectly adjusted. operating manual of the controller).
  • Page 15: Annex

    Annex Accessories and Spare Parts Also see the illustration on page 7. Pos. Description Loctite Order No. Luer-Lock-Adapter Kit ..................97233 Integrated Non-return Valve 6 bar..............8964738 Non-return Valve 0.4 bar ................... 8964737 Sealing Rings Repair Kit ................... 8964709 Reservoir Fitting ¼” * ⅛” ................... 8900064 –...
  • Page 16: Manufacturer's Declaration

    A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted to Loctite in writing within one month after discovery of the defect or after the time the defect should reasonably have been discovered [and in any event within six months after the delivery of the Products to the purchaser].
  • Page 17 8964739 – 03/2003...
  • Page 18 Henkel Loctite Deutschland GmbH Arabellstra e 17 Telefon 0 89/92 68-0 D-81925 M nchen Telefax 0 89/9 10 19 78 Henkel Loctite Corporation 2003...