Electrical Interface

Input signals

Trigger Input

When the Trigger line is pull low for 10 ms, the Engine starts a read. The Engine keeps reading until a
successful reading, a timeout or the line is high. After a successful reading, the line must go high in order to
make another read.

A Sample Schematic of Trigger Input Circuit

Here is a schematic from the evaluation board, EVK3000&1300. The signal can connect to external device's
output port.