Denso BHT-825QW User Manual page 153

2d code handy terminal
Table of Contents

Advertisement

BHT-825Q series
"2: SET PING" (PING Options Setting Screen)
1.
Select "2: SET PING" at the TEST PING menu and then press the
ENT key.
The current settings are displayed.
[1: DESTINATION IP]:
Specifies the IP address of the host computer to be pinged.
[2:DATA SIZE]:
Specifies the data size of the echo request.
[3:INTERVAL]:
Specifies the echo request interval (in units of 100 ms).
[4:TIMEOUT]:
Specifies the timeout period (in units of 100 ms) for the echo request.
[5:COUNT]:
Specifies the number of echo requests to be sent.
[6:SEND TYPE]:
Selects the echo request send timing (TYPE 1 or TYPE 2).
(Refer to "PING Echo Request Transmission Timing (SEND TYPE)" on the following page for details.)
2.
Use the cursor keys ([▲] [▼]) or numerical keys ([1] [2] [3] [4] [5] [6]) to highlight the item to be
set, and then press the ENT key.
The mode changes to entry mode and the cursor displays.
Use the cursor keys ([◄] [►]) to highlight the "6: SEND TYPE" setting.
3.
Enter the setting values with the numerical keys and dot key.
To delete a single character, press the BS/C key. To delete the entire entry,
press and hold the BS/C key, or press the SF key and BS/C key simultaneously.
4.
Enter the setting values and then press the ENT key.
Press the BS/C key to return to the TEST PING menu.
Entry Range for DATA SIZE, INTERVAL, TIMEOUT, and COUNT
Item
DATA SIZE
INTERVAL
TIMEOUT
COUNT
* Specifying zero (0) will set the number of echo requests to "infinite," meaning that echo requests will be
sent continuously until the PING test is aborted.
If a value outside the allowable entry range listed above is specified, the nearest value within the range
will automatically be applied.
138
Allowable Entry range
4 to 1472
0 to 65535
0 to 65535
0
*
to 65535
Default
56
10
10
4