Consult with your local building code agency and insurance
representative before you begin your installation to ensure
compliance with local codes, including the need for permits
and follow-up inspections.
Several issues must be addressed when selecting a
suitable location for your Advance Pellet Stove. Observing
required clearances to combustible materials, the proximity
to a safe chimney or venting system, and the accessibility
of electrical supply must all be considered. In addition,
selecting a location that takes advantage of the building's
natural air flow is also desirable to maximize the heating
effectiveness of the heater. In many cases, this is a central
location within the building.
Place the stove on a noncombustible floor or a floor
protector that extends 6" (152mm) to the front, 6" (152mm)
to the sides and 1" (25mm) to the rear of the stove. In the
US, the front and side floor protection is measured from
the door opening. In Canada, the measurements are from
the appliance. (Fig. 8.) Floor protection must be placed
under any horizontal venting. This protection must extend
a minimum of 2" (51mm) beyond each side of the pipe.
Place the stove away from combustible walls at least as
far as shown in figures 6, and 7. The clearance to a ceiling
above the appliance is 24" (608mm).
Note that the clearances shown are minimum for safety,
but do not leave much room for access when cleaning or
servicing. Please take this into account when placing the
stove.

mobile home Installation

When installing this stove in a mobile home several
requirements must be followed:
1. The unit must be bolted to the floor. This can be done
with 1/4" lag screws through the 2 holes in
plate shown in Fig. 11, Page 10.
2. The unit must also be connected to outside air. See page 14.
3. Floor protection and clearances must be followed as
shown.
4. Unit must be grounded to the metal frame of the mobile
home.
5. WARNINg - dO NOT INSTALL IN A SLEEPINg ROOM.
CAuTION: This appliance must be vented to the outside.
The factory-built chimney must conform to CAN/ULC-S629,
Standard for 650°C Factory-Built Chimneys. Use the vent or
chimney manufacturer's components to provide an effective
vapor barrier where the vent penetrates to the exterior.
The top section(s) of chimney must be removable to a
maximum height of 13' (3.9 M) to allow transport.
Installation and repair of this stove should be done by a
qualified service person. The appliance should be inspected
before use and at least annually by a qualified service
person. Frequent cleaning will be required. It is imperative
that control compartments, burners, and circulating air
passageways of the stove be kept clean.

Installation

6"
(152mm)
the base
ThE STruCTurAl INTEgrITY OF ThE
mANuFACTurEd hOmE FlOOr, wAll, ANd
CEIlINg/rOOF muST bE mAINTAINEd.
KEEP ChIldrEN, ClOThINg, ANd
CONTACT mAY CAuSE SKIN burNS.
9
7"
178mm
Fig.6
1"
25mm
Fig.7
1"
FLOOR
6" (152mm)
PROTECTOR
Fig.8
CAuTION
CAuTION
hOT whIlE IN OPErATION.
FurNITurE AwAY.
6"
(152mm)