The Advance pellet stove is more than just automatic ignition, it is also automatic temperature
control. The automatic system will allow the fire size to be adjusted to match the heating
needs and even put the fire out if necessary. If heat is needed after the fire is out, the Advance
will automatically re-ignite and adjust the fire size to match the heating need. The totally
automatic room sensor mode is recommended because of its efficiency.
The unit can be switched between "AUTO" and "MANUAL" at any time during operation.
Room Temperature Mode: This setting will produce a room
temperature of 70 degrees with the distribution blower at medium
speed.

Stove Temperature mode

This setting will produce medium heat with the
distribution blower on "low".
This setting will produce continuous maximum heat
output with the distribution blower at full speed.

Automatic Ignition/Operation

Igniter switch to "AuTO"

room Temperature mode

In "Room Temp Mode" heat output is controlled
automatically by the Room Sensing Probe. When
the Room Sensing Probe calls for heat, the stove will
increase output. When the Room Sensing Probe is
getting close to the set temperature, the stove will begin
to level off output and keep the fire burning at just the
right temperature to maintain that setting.
High output is determined by the feed rate setting.
This setting, generally on #4, can be increased if higher
burn rates are necessary. The unit's maximum burn
rate should not create less than 1" of ash on the burn
pot front edge. See Fig.2, Page 5. Overfeeding is not
a safety concern, but fuel may be wasted if unburned
pellets fall into the ash pan.
In "Room Temp Mode" a constant fuel consumption rate
is sacrificed for exact room temperature. Therefore, as
it gets colder more pellets will be burned automatically.
The distribution blower speed will vary according to
the position of the mode selector pointer, and fire size.
Igniter switch to "AuTO"
Stove Temperature mode
This allows for automatic ignition upon start-up only.
The unit can then be set at any desired setting. The
heat output and fuel consumption will remain constant
regardless of room temperature. The unit's maximum
feed rate should not create less than 1" of ash on the
burn pot front edge. See Fig 2, Page 5.
The unit's low burn or maintenance setting is as low
as it will go. It will not go out unless it runs out of fuel
or is turned off.
Shut-down procedure
To kill the fire or stop burning the stove, turn the Mode
Selector to "OFF". This will cause the fire to diminish and
burn out. When the fire burns out and the stove cools down
everything will stop.
If you pull the plug to shut down the stove, all motors will
stop. This may cause incomplete combustion and smoke in
the firebox. If the load door is opened the smoke may escape.
The best way to shut down the stove is simply let it run
out of pellets, then the stove will shut down automatically.