E. Automatic Ignition
Figure 4.6
1. Fines are small pieces of broken pellets (sawdust). Fines
do not flow easily and often build up on the hopper funnel
bottom angles. These fines can be pushed into the feeder
opening and then fill the hopper with pellets. As the system
works, they will be burned.
2. The "TEST" cycle will operate the feed motor for exactly
one minute. Turning to "TEST" again and again may load
too much fuel into the burn pot causing excessive smoke on
start-up.
3. The firebox low pressure switch will not allow the auger motor
or the igniter element to operate if the view door is open.
4. Adjust Feed Rate. If this is your first fire or you are trying
different pellets, set the Feed Limit to #4, Figure 4.6 This is a
conservative number and will probably need to be increased.
After you know a feed rate setting that works well, use that
setting. Remember, if your feed rate is too high you may
waste fuel.
5. This is usually a weekly maintenance procedure. Cleaning
the burn pot with the scraper with a small amount of new fuel
in the bottom is not a problem. First, scrape the ashes off
the front of the burn pot into the ash pan. Then scrape the
holed surface downward into the burn pot. When the stove
feeds, these scrapings will be pushed out by the feeder.
6. The ash pan can hold the ashes from approximately 1 ton
of premium fuel. This means the ashes will only need to be
emptied a few times a year.
7. Setting the Feed Limit # for maximum burn: With the unit
burning in "AUTO", turn to "Stove Mode" and put the fan on
"H". Set the Temperature Dial to #7. Allow the unit to burn for
about 30 minutes and check ash on front of burn pot. Figure
4.7. If the ash line is larger than 1", turn the Feed Limit from
#4 to #5. Allow another 30 minutes of burn time and check
again. If, at #6 setting, a 1" or less ash bed is not obtainable,
it is not a problem. The 1" ash bed is only at maximum burn
rate and during normal operation, the ash bed will be larger.
12
See Note 7
1"
Figure 4.7
Harman® • Accentra Owner's Manual_R40 • 2002 -___ • 11/15
Igniter Switch to "AUTO" (up position)
Make sure the unit is plugged into a properly grounded, 120
VAC, 60 Hz electrical source. The power light should be the
only light lit.
Note: Be sure there is no fuel or other combustibles in
the ash pan prior to lighting.
1. Turn Mode Selector to "OFF".
2. Fill hopper with pellets.
3. Clean burn pot with scraper, if necessary.
4. If starting after an empty hopper, turn Feed Limit to "TEST"
(for one 60 second cycle).
auger tube and also allow you to check the motors for
operation.
NOTE: The auger motor will not operate with the view
door open.
5. Turn Feed Limit to #4.
6. Flip the Igniter Switch up into the "AUTO" position.
7. Turn the Temperature Dial to the desired room temperature.
8. Turn Mode Selector to Room Temperature or Constant
Burn.
9. Fill hopper with pellets and remove ashes as required.
Keep the hopper lid and firebox doors closed while in
operation. Maintain door seals in good condition. Failure
to do so will affect operation of the appliance and may
permit escape of smoke or gases into the living space.
!
BURNING GARBAGE, USE OF IMPROPER FUELS,
FIRE STARTERS OR ALTERING THE STOVE FOR
HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO
THE STOVE AND COULD RESULT IN A HOUSE FIRE.
USE ONLY APPROVED FUELS AND FOLLOW ONLY
THESE OPERATION GUIDELINES.
!
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR 'FRESHEN UP' A FIRE
IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL
AWAY FROM THE HEATER, WHILE IN USE.
This will flow pellets into the