Personal Programming Of The Dive Computer (Datatalk) - Uwatec Aladin Air z Operating Manual

Table of Contents

Advertisement

1 MemoMouse, DataTrak and DataTalk
The Aladin
Air Z is able to communicate with a personal computer. The connection is established by
®
contact sensors and the MemoMouse. The MemoMouse and the PC software DataTrak and DataTalk is
available as an option. For the Aladin
Communication with a personal computer (Windows

1.1 Personal programming of the dive computer (DataTalk)

Several parameters can be set individually by the user, e.g.:
– The physical units of water depth and tank pressure can be selected (Metric/Imperial).
– The calculation of Remaining Bottom Time (RBT) assumes a remaining tank pressure at the surface. This
remaining pressure can be adjusted from 30 to 100 bar.
– The acoustic alarm can be switched off for attention messages. Actual alarms are not changed (not
enough air, ignoring decompression stop, too rapid ascent).
– The sensitivity of the message «out of breath» can be altered.
1.2 Analysis and storage of real dives
The last approx. 200 minutes of dive time are stored by the dive computer in increments of 20 seconds
and can be transferred to the PC. The DataTrak software allows the representation and analysis of the pro-
files. By this means all relevant data are examined and displayed for every point in time. The DataTrak
releases 1.6 and higher recognize the Aladin
The PC program enables the diver to keep a personal logbook. Apart from the last 200 minutes of diving,
37 dives are recorded in the logbook of Aladin
larly into the MemoMouse and then to the PC, all dives will be stored in the PC with their profiles.Time
and date of the dives are automatically recorded and the dives can be printed out on a page for the diver-
's logbook.
1.3 Updates
The last versions of DataTrak and DataTalk are available for free from the Internet
(http://www.uwatec.com).
74
®
Air Z it is only allowed to use DataTalk version 1.6 or higher.
• If you switch off the acoustic attention buzzer of the Aladin
pay careful attention to the visual signals on the face of the Aladin
Failure to follow all alarms whether audible or not may lead to serious injury
or death due to decompression sickness, and/or drowning.
®
Air Z and display the respective data.
®
®
) has a number of advantages:
Air Z. If the data from Aladin
®
Air Z you must
®
Air Z.
Air Z are transferred regu-
®
VII Uwatec
Aladin
®
®
Air Z

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents