Trouble Shooting - Uwatec Aladin Air z Operating Manual

Table of Contents

Advertisement

VIII Trouble Shooting
symptom
No reception of tank
pressure data.
Bad reception of tank
pressure data.
Displayed tank pressure
does not correspond
to pressure measured
by a manometer (pres-
sure gauge).
76
possible reason(s)
Transmitter and computer are not
tuned to each other (paired).
Transmitter or receiver in the compu-
ter are defective.
In surface mode if there is no decrea-
se in pressure for 3 minutes the pres-
sure data will not display.
Transmitter is not mounted correctly.
Transmitter, or receiver in the compu-
ter are defective.
By compensating the temperature,
the pressure displayed is valid at
20 °C.
If air- or water-temperature differ
from this value, a difference to the
value given by a pressure gauge is
possible.
Tank and transmitter do not have the
same temperature (only possible in air).
Manometer/pressure gauge is not
accurate (temperature 20 °C).
procedure(s)
Pair transmitter and computer
(see chapter II 4).
If the pairing is not possible with ano-
ther transmitter, the receiver in the
computer is defective. Have transmit-
ter or dive computer repaired.
Change the pressure by breathing
from the regulator. Tank data will re-
appear.
Mount transmitter correctly
(see chapter II 4)
If the pairing is not possible with ano-
ther transmitter, the receiver in the
computer is defective. Have transmit-
ter or dive computer repaired.
Make comparison at 20 °C or check
the tank pressure compensated to
the atmospheric pressure for com-
parison (see appendix, chapter IX).
Leave the tank with the regulator
mounted in the open air for 5 -10
minutes.
Measure tank pressure with another
manometer/pressure gauge (at 20 °C).
VIII Uwatec
Aladin
Air Z
®
®