ZXR10 8900 Series User Manual (Ethernet Switching Volume)
Example
Illustration and
Networking
Diagram
Switch
Configuration
102
Confidential and Proprietary Information of ZTE CORPORATION
Command
Debug cfm pkt [megid | all
ZXR10#
|{md <md-index> ma <ma-index> mep
<mep-id>}][direction {send | rcv |
all}>]{pkt-nums <inter>}
OAM Link Control Event
Configuration Example
OAM monitor function can advertise abnormal frames on receiving
end of link to the local in a specific mode. This function is realized
based on OAM-discovery-success. After logs into switch through
console port, user configures OAM function, enables OAM function
on peer interface, and enables link monitor function on the peer
interface, error symbols and error frames in the link can be de-
tected and advertised to local switch.
F
34 L
C
IGURE
INK
ONTROL
�
Configuration of switch A:
ZXR10(config)#set ethernet-oam enable
ZXR10(config)#interface gei_1/2
ZXR10(config-gei_1/2)#set Ethernet-oam enable
�
Configuration of switch B:
ZXR10(config)#set ethernet-oam enable
ZXR10(config)#interface gei_1/1
ZXR10(config-gei_1/1)#set ethernet-oam enable
ZXR10(config-gei_1/1)#set ethernet-oam link-monitor enable
ZXR10(config-gei_1/1)#set ethernet-oam link-monitor
symbol-period threshold 10 window 10
ZXR10(config-gei_1/1)#set ethernet-oam link-monitor
frame threshold 10 window 20
ZXR10(config-gei_1/1)#set ethernet-oam link-monitor
frame-period threshold 5 window 1000
ZXR10(config-gei_1/1)#set ethernet-oam link-monitor
frame-seconds threshold 10 window 30
ZXR10(config-gei_1/1)#show ethernet-oam gei_1/1 link-monitor
Link Monitoring of Port: 1
Errored Symbol Period Event:
Symbol Window : 10(million symbols)
Errored Symbol Threshold : 10
Total Errored Symbols
Local Total Errored Events
Remote Total Errored Events : 0
Errored Frame Event:
Period Window : 20(s)
Errored Frame Threshold : 10
Total Errored Frames
E
N
VENT
ETWORKING
: 0
: 0
: 0
Function
This debugs CFM
functional module in
privileged mode.