Specifications

Environmental

Temperature:
Relative humidity:
(non-condensing)
Maximum altitude:
Temperature:
Relative humidity:
(non-condensing)
Maximum altitude:

Acoustic

Geräuschemission LpA = 59.2 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LpA = 59.2 dB in a virtual workspace according to
DIN 45635 T.19

Network Connectors

A-2
Operating
0°C to 40°C (32°F to 104°F)
15% to 95% at 55°C (131°F)
3.0 km (10,000 ft)
TRANSCEIVERS
SR Optic J8436A
0°C to 40°C (32°F to 104°F)
LR Optic J8437A
ER Optic J8438A
LRM Optic J9144A
Copper J8440B
15% to 95% at 40°C (104°F)
3.0 Km (10,000 ft)
The 10/100 Mbps RJ-45 twisted-pair ports on the 10/100-TX zl Module are
compatible with the IEEE 802.3 10Base-T and IEEE 802.3u 100Base-TX
standards.
The 100/1000 Mbps RJ-45 twisted-pair ports on the 100/1000-T zl Module
are compatible with the IEEE 802.3u 100Base-TX and IEEE 802.3ab
1000Base-T standards.
The 1000 Mbps fiber-optic ports on the Gigabit-SX and Gigabit-LX
mini-GBICs are compatible with the IEEE 802.3z Gigabit-SX and
Gigabit-LX standards respectively.
The copper ports are compatible with the IEEE 802.1ak standards.
Non-Operating
-40°C to 70°C (-40°F to 158°F)
15% to 95% at 65°C (149°F)
4.6 km (15,000 ft)