8. Secure the strain relief around each set of wires and insert them into a convenient hole in the lower edge of
the chassis. It is recommended that you secure the wires with tie wraps every 12 inches from the strain
relief to the DC source so as not to disturb the field wiring.
9. Close the on-site (over-current) protection device to supply power to the inlet(s) of the Tenor CMS.
The chassis power connections are now complete. With the WAN cards and power supplies secured to the
chassis, close the circuit breaker(s) on the Tenor CMS. Verify that the STATUS LEDs on the power supplies
are green a few seconds after turn on.