Winston Industries PF46C Owner's Manual page 24

Winston collectramatic fryer owner's manual  
Table of Contents

Advertisement

PRoGRammInG
PRocESS 2
Programming Process #2 (PC 2) - 6 temperatures, 6 times, load
compensation
StEP 1
First choose the channel you want to program.
2
3
4
5
6
WHEN THE
COMPUTER DISPLAYS
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
Step 14
Step 15
Return to STEP 6 and repeat through STEP 15 until bu1 displays, then go to STEP 16
Step 16
Step 17
Step 18
Note: At any time during programming, time settings can be set to :00 indicating from that point on, the fryer will cook at the last
setting entered until the end of the cycle.
24
7
8
PRESS
BUTTON/ACTION
ENTER
2
ENTER
HEAT SETPOINTS H1 THROUGH H6
or
ENTER
HEAT SETPOINTS T1 THROUGH T6
or
ENTER
ENTER
ENTER
PRE-ALARM SETPOINTS 1 THROUGH 3
or
ENTER
www.winstonindustries.com | 1.800.234.5286
StEP 2
In sequence, press the following buttons to enter
programming mode.
PROG
then
then
then
NOTE
Indicates Programming mode. Press ENTER to proceed.
Press channel button #2 for selecting process #2.
Press ENTER to proceed.
H1 displays momentarily. Repeat from here for H2 through H6.
Use arrow buttons to modify. Hold either button for fast scrolling. Will
display in F or C. 250˚F (121˚C) minimum, 360˚F (182˚C) maximum.
Press ENTER to proceed.
t1 displays momentarily.
Repeat for t2 through t6. Remember t1=total cook time, and times t2
through t6 indicate time remaining in the cook cycle.
Use arrow buttons to modify. Hold either button for fast scrolling. Display
shows MM:SS (minutes:seconds). :00 minimum 99:55 maximum.
Press ENTER to proceed.
Use arrow button to toggle between Open (O) and Pressure (P).
Controller proceeds to next heat setpoint (repeats starting at
STEP 6). If at final pressure setting, program mode exits.
Use arrow button to toggle between Straight Time (Str) and Load
Compensation (Lc).
Controller proceeds to next heat setpoint (restarts at STEP 6). If at final
pressure setting, proceed to STEP 16.
bu1 displays momentarily. Repeat STEP 16-18 for pre-alarms bu 2 through
bu 3.
Use arrow buttons to modify. Hold either button for fast scrolling. Display
shows MM:SS (minutes:seconds)
Press ENTER to exit programming mode.