Winston Industries PF46C Owner's Manual page 23

Winston collectramatic fryer owner's manual  
Table of Contents

Advertisement

PRoGRammInG
PRocESS 1
Programming Process #1 (PC 1) - 6 temperatures, 6 times
StEP 1
First choose the channel you want to program.
2
3
4
5
6
StEP 2
In sequence, press the following buttons to enter programming mode.
PROG
then
then
then
WHEN THE
COMPUTER DISPLAYS
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
REtURn to StEP 6 anD REPEat tHRoUGH StEP 13 UntIl PRoGRammInG IS comPlEtE.
Note: At any time during programming, the time setting can be set to :00 indicating from that point on, the fryer will cook at the last temperature
setting entered until the end of the cycle.
Need to coNtact us?
www.winstonindustries.com | E-mail customerservice@winstonind.com
Phone 1.800.234.5286 | 1.502.495.5400 | 1.502.495.5458 • Mail 2345 Carton Drive | Louisville, KY 40299 USA
7
8
then
PRESS
BUTTON/ACTION
ENTER
1
ENTER
HEAT SETPOINTS H1 THROUGH H6
or
ENTER
HEAT SETPOINTS T1 THROUGH T6
or
ENTER
ENTER
FRYERS
NOTE
Indicates Programming mode. Press ENTER to proceed.
Press channel button #1 for selecting process #1.
Press ENTER to proceed.
H1 displays momentarily. Repeat from here for H2 through H6.
Use arrow buttons to modify. Hold either button for fast
scrolling. Will display in F or C. 250˚F (121˚C) minimum, 360˚F
(182˚C) maximum.
Press ENTER to proceed.
t1 displays momentarily.
Repeat for t2 through t6. Remember t1=total cook time, and
times t2 through t6 indicate time remaining in the cook cycle.
Use arrow buttons to modify. Hold either button for fast
scrolling. Display shows MM:SS (minutes:seconds). :00 minimum
99:55 maximum.
Press ENTER to proceed.
Use arrow button to toggle between Open (O) and Pressure (P).
Controller proceeds to next heat setpoint (repeats starting at
STEP 6). If at final pressure setting, program mode exits.
23