16.0 Specifications

Table 13: D6600/D6100i Specifications

Dimensions
D6600
(H x W x D)
D6100i
Weight
D6600
D6100i
D6600 Power Input
AC Nominal Operating Range
AC Maximum Operating Range
D6100i Power Input
AC Nominal Operating Range
Current Required
D6600 with one line card installed
For each additional line card or
terminal card pair
For network communications card
D6100i
Standby Power
The receiver includes an external battery connection and battery harness. Use 12 V rechargeable sealed lead-
acid batteries. A 4-hour minimum standby power supply (UPS or battery) is required for UL Certification (refer
to Section 8.1 Connecting External Batteries on page 14 for battery size).
Telephone
RJ11C modular jacks, with 26 AWG or larger wire diameter.
FCC Registration
D6600 ESVUSA-25328-AL-N
D6100i ESVAL04BD6100
The D6600 Receiver is Federal Communications Commission (FCC) registered under Part No. 68 using the
RJ11C Interconnect that can be ordered from your local telephone company.
Notice: This equipment has been tested and found to comply with the limits for a Class A (D6600) or Class B
(D6100i) digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Any modifications made to this device that are not approved by Bosch Security Systems, Inc. may void the
authority granted to the user by the FCC to operate this equipment.
Ringer Equivalence
0.4 B
34
Rack mount (4U)
Standalone
Rack mount (2U)
Standalone
8.7 kg (19 lb)
3 kg (7 lb)
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Specifications
18 cm x 48.3 cm x 49.5 cm
(7.0 in. x 19.0 in. x 19.5 in.)
18 cm x 45.0 cm x 49.5 cm
(7.0 in. x 17.75 in. x 19.5 in.)
9.0 cm. x 37.5 cm. x 25.5 cm
(3.5 in. x 19 in. x 10 in.)
9.0 cm. x 30.5 cm. x 25.5 cm
(3.5 in. x 12.0 in. x 10 in.)
120 V or 230 V
100 VAC to 120 VAC, 220 VAC to 230 VAC, 50 - 60 Hz
2.5 A maximum
18 VAC, 40 - 50 VA Transformer
Required battery current
Required UPS AC standby current
Required additional battery current
Required additional UPS AC standby current
Required additional battery current
Required additional UPS AC standby current
Required battery current
Required UPS AC standby current
Bosch Security Systems, Inc. | 9/08 | 4998122704-04
800 mA
350 mA
210 mA
35 mA
10 mA
10 mA
330 mA
180 mA