Conettix D6600/D6100i | Installation and Operation Guide | 3.0
.
Table 3: System Trouble LED
No System Trouble
Any System Trouble*
*
Refer to Appendix B: D6600/D6100i Internal Messages in
the D6600/D6100i Computer Interface Manual
(P/N: 4998122703). The following items cause system
trouble. Depending on the supervision setting, the items
indicated by ** might cause system trouble.
Battery Missing**
UPS AC Fail
Battery Bad**
UPS Battery Low
AC Fail
System Temperature
High
3.1.2

Line Cards and Modules

Table 4: D6600 Line Cards and Modules
Name
Model
Description
Telephone
D6640
Up to eight line cards can be
line card
installed in one D6600 Receiver, for
up to 32 telephone line connections.
Telephone
D6641
Functions like the D6640. Includes
line card
improved Public Switched
Telephone Network (PSTN)
processing, additional memory for
future enhancements, and single
firmware upgrade package.
CPU card
D6610
The D6600 uses one CPU card. The
CPU card takes the incoming
information from the line card and
routes the information to an
automation port, the LCD on the
front of the receiver, and an external
printer.
Power
D6630
The power supply modules regulate
supply
and
the power used by the D6600.
modules
D6631
These are not field serviceable.
Telephone
D6645
Located behind the line card, the
line
tele-phone line terminator card
terminator
isolates and protects the line card
card
against out-side voltage surges that
might come over the telephone line.
Each line card must have a line
terminator card.
CPU
D6615
Located behind the CPU card, the
terminator
CPU terminator card provides the
card
D6600 with two serial ports (COM3
and COM4), a parallel port (parallel
printer), and a general I/O port (I/O).
The serial ports can be used for
computer automation, PC
connection for programming, or a
network connection with a D6680.
Bosch Security Systems, Inc. | 9/08| 4998122704-04
System Trouble LED Status
Solid Red
Clear
External Printing Error**
Line Fault**
COM# Error**
Line Card Trouble**
COM3 Trouble**