2. Level III Line Security for ULC-S303 and ULC-
S304.
3. Phone lines have not been evaluated for line
security.
In order to implement the Standard or Encrypted Line
Security over the private or public IP networks, the
firmware version must be 1.8.2.1. The firmware was
evaluated for 128-bit encryption.
Supervision signals between premises alarm
equipment and supervising station alarm receiver
equipment shall be managed by the supervising
station receiving equipment and not an intermediary
network agent, device or service.
UL Standard 827 also states that you must be able to
switch from one receiver to a standby receiver within
30 sec, and repair the faulty receiver and return it to
service within 30 min.
NFPA 72 requires that if more than eight telephone
lines are used, the receiving equipment must be
completely duplicated so switchover can be
accomplished in 30 sec (per NFPA 72-1996
4-5.3.2.2.1.1).
Table 5:
Parameters to be set
Programming
Parameter to be
Item (location in
Set
Prog. Manual)
2.2.21 Buzzer
Set to "1" to
sound on all
events. May be
set to "3" when
used with an
automation
system to
sound only
when the
automation link
fails.
2.2.33 External
Set to "1" to
Parallel Printer
print all events.
May be set to
"3" when used
with an
automation
system.
2.2.34 Battery
Set to "1" to
Supervision
activate.
3.1.2.1 Phone
Set to "1" to
Supervision
enable.
Bosch Security Systems, Inc. | 9/08| 4998122704-04
Conettix D6600/D6100i | Installation and Operation Guide | 7.0
Location in
Operation &
Inst. Manual
Page 19,
section 10.1.6
Page 19, 10.1.7
Page 14, 8.0
Page 11, 4.1.3
7.3

Burglar Alarm Applications

For commercial fire and burglary,
proprietary and central station
application that are using BIS, the BIS
application shall be installed on the
Listed Bosch model B-010 computer
with Bosch model B-008 monitor and
SC9002 printer connected.
Figure 11: Location of D6100i Battery
Terminals and D6600 Battery
Connector
D6100
D6600
Bosch Security Systems
Fairport, NY
USA
B
A
T
T
E
R
Y
Input:
100 - 120/
220 - 240V~
50 - 60 Hz
2.5 Amps
Receivers are not shown to scale.
Install the D6600/D6100i according to UL Standard
827 for Central Station Burglar Alarm Systems. Use in
a central station that has backup AC power (per UL
827) to supervise certificated accounts.
Terminals for connection of external batteries are on
the rear of the receiver (Figure 11).
7.4

Fire Alarm Applications

The D6600/D6100i can be used for Central Station
Protective Signaling when it is installed and used in
compliance with NFPA 72 and ANSI/NFPA 70.
Installation limits for digital alarm communicator
receivers (DACR) are under the local AHJ.
7.5

Installation Check List

1. Check each receiver card to see that it is correctly
positioned in the card guides at the top and
bottom of the enclosure. Also confirm that
connections did not loosen during shipment
(D6600 only).
2. Ensure that the earth ground is connected and
grounded through the AC inlet.
3. If you are installing additional line cards, install
the terminator cards now (D6600 only).
Installation
1
2
1
B
A
2
T
3
T
E
4
R
Y
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100i

Table of Contents